Performance requirements of miniature current transformers
Jun 25, 2021| One of the remarkable features of the miniature current transformer is that it has an ultra-small shape and structure design, and it has a high precision. We know that current transformers work according to the principle of electromagnetic induction. The miniature current transformer is composed of a closed core and windings. The current transformer is similar to the transformer and also works according to the principle of electromagnetic induction. The transformer transforms the voltage and the current transformer transforms the current.
The performance requirements for miniature current transformers mainly include four aspects: 1. Insulation requirements; 2. Overload capacity requirements; 3. Temperature rise requirements; 4. Upper temperature and lower temperature requirements. The insulation requirements include the insulation requirements between the primary and secondary windings, that is, the fixed rated power frequency withstand voltage between the primary winding and the secondary winding is 3kV (root mean square value). When the insulation requirements are specified in accordance with the Class II protective insulation requirements, the power frequency withstand The receiving voltage is 4kV (root mean square value).
The second is the insulation requirements between the two primary windings and the secondary windings in the miniature current transformer: the rated power frequency withstand voltage between the primary windings is 3kV (root mean square value). When the insulation requirement is specified as Type II protective insulation, The frequency withstand voltage is 4kV (root mean square value). As for the impulse voltage tolerance requirements between the primary winding and the secondary winding: the primary winding and the secondary winding can withstand an impulse voltage of 6kV and a waveform of 1.2ms/50ms. For class II protective insulation transformers, the primary winding and the secondary winding can withstand an impulse voltage of 8kV and a waveform of 1.2ms/50ms.
For the overload capacity requirements of the miniature current transformer, it means that the transformer is still intact after the corresponding test under the rated load, and when it returns to the rated current to work, the error of the transformer does not exceed the specified error limit. 1.3 times, after demagnetization, the transformer meets the original accuracy level requirements.
The temperature rise requirement refers to that when the ambient temperature is 40℃, the surface temperature rise of the miniature current transformer shell under Imax current does not exceed 25K. At the same time, under the upper limit temperature and the lower limit temperature, the transformer still meets its accuracy level requirements.