What are the precautions for grounding the secondary side of the current transformer?

Jan 22, 2025|

1. Grounding location and method
Single-point grounding principle: The secondary side of the current transformer should adopt a single-point grounding method. This is to avoid the formation of a ground loop by multi-point grounding, because the ground loop may introduce additional interference current and affect the measurement accuracy. It is usually chosen to ground at a location close to the secondary terminal of the current transformer, such as grounding in the secondary junction box of the transformer. This ensures the shortest grounding path and reduces the possibility of interference.
Grounding reliability: The grounding connection must be firm and reliable. Appropriate grounding terminals and grounding wires should be used, and the cross-sectional area of ​​the grounding wire must meet certain requirements, generally not less than 4 square millimeters. For example, in an industrial environment, a copper grounding wire can be used and firmly connected to the grounding terminal by bolting, etc., to ensure that the current can be effectively introduced into the earth in the event of a fault.
2. Grounding wire selection
Conductivity requirements: The grounding wire must have good conductivity to ensure that the current can be quickly introduced into the earth in the event of a fault. In addition to the copper wires mentioned above, other highly conductive materials can also be selected, but their corrosion resistance and mechanical strength must be considered. For example, in some occasions with special corrosive environments, tinned copper wires can be used, which not only ensures conductivity but also enhances corrosion resistance.
Insulation sheath requirements: Grounding wires usually need to have an insulating sheath to prevent accidental contact with other live parts during normal operation. The insulating sheath should have good insulation performance and mechanical wear resistance, and be able to adapt to different working environments. For example, in outdoor environments, the insulating sheath of the grounding wire must be able to withstand ultraviolet radiation, wind and rain erosion, etc.
3. Cooperation with other equipment
Prevent electromagnetic interference: When installed with other electrical equipment, care should be taken to avoid electromagnetic interference from other equipment to the secondary side grounding system of the current transformer. For example, when the current transformer is close to large motors or transformers and other equipment, the magnetic field generated by these equipment may induce electromotive force in the grounding loop. Therefore, it is necessary to arrange the layout of the equipment reasonably, or take electromagnetic shielding measures, such as using a metal shielding cover to surround the current transformer and its grounding system to reduce the impact of external electromagnetic interference.
Cooperation with relay protection devices: In the relay protection device of the power system, the secondary side grounding of the current transformer is particularly important. It is necessary to ensure that the grounding system does not affect the normal operation of the relay protection device. At the same time, the grounding of the relay protection device and the grounding of the secondary side of the current transformer should be coordinated with each other. For example, when designing the protection system, the current flow direction during ground fault should be taken into account to avoid false operation or refusal of protection, and ensure that the protection device can accurately detect the fault and act in time.
4. Maintenance and inspection
Regularly check the grounding resistance: The grounding resistance is an important indicator to measure the effectiveness of the grounding system. Regularly check the grounding resistance of the secondary side of the current transformer to ensure that it does not exceed the specified value. Generally speaking, the grounding resistance should be less than 10 ohms. You can use a grounding resistance tester for detection. If the grounding resistance is found to be too high, check whether the grounding connection is loose, whether the grounding electrode is corroded, etc. in time, and take corresponding repair measures.
Check the integrity of the grounding wire: In daily maintenance, check whether the grounding wire is intact. Including checking whether the wire is broken, whether the insulation sheath is damaged, etc. If the grounding wire is found to be damaged, it should be replaced in time to ensure the normal operation of the grounding system.