Causes of current transformer damage and treatment measures

Sep 03, 2022|

There are many reasons for the damage of the current transformer. If the direct cause is found, then the symptom can be treated and the countermeasures can be adopted immediately. The key to this strategy is:

1. Install the isolation switch to prevent the common faults of the branch from spreading to the power outage of the whole line, especially to ensure that the branch isolation switch can reliably trip.

2. Connect the current transformer to the back of the isolating switch to ensure that the isolating switch and the zinc oxide arrester are properly positioned to remove common faults when the common fault of the voltage transformer occurs.

3. Improve the high-voltage insulation layer test of the customer's current transformer and zinc oxide arrester, find out the embrittlement level of the insulation layer of the voltage transformer and the zinc oxide arrester as soon as possible, and immediately replace it to prevent the occurrence of a power outage caused by the burning of the voltage transformer.

4. The other is to clean up the customer's machinery and equipment on time to reduce environmental pollution and prevent the reduction of the insulating layer.


The current transformer will smoke and destroy the original feeling, and there will be a strong odor; the working voltage of the insulation layer monitoring wireless water meter will be reduced, the marking of the ammeter, active and reactive power meters will be reduced, and the voltage of the generator set will be reduced. When the transformer emits smoke, the photon sign of "motor stator grounding device" will light up, and the busbar voltage transformer will emit smoke, and there will be photon signs such as "working voltage control circuit disconnected", "backup power supply subsidence" and so on. Solution: If the high-voltage fuse has never been blown before the voltage transformer starts smoking, and the high-voltage fuse is blown several times again, and the smoking is not serious, there is no damage to the insulation layer. If the high-voltage fuse is not blown, it should be determined that the short-circuit fault between the windings of the voltage transformer has caused smoke. Before the smoke is generated by the winding again without harming the destruction of the primary insulation layer, immediately withdraw the relevant maintenance and protection. Install the device, take out the high-voltage fuse again, open the isolation switch once, and stop using the voltage transformer.

For oil-filled voltage transformers, if the smoke is accompanied by a strong odor, there is abnormal noise inside the voltage transformer; there is corona discharge between the windings and the casing or between the wires and the casing; When the high-voltage fuse blows 2~3 times and other conditions, it should be distinguished that the insulation layer of the primary side is damaged and smoke is generated. If it is the voltage transformer of the generator set, the method of disconnecting the generator set should be used first. If it is the voltage transformer of the busbar, stop the use of the voltage transformer by stopping the busbar. At this time, it is never allowed to stop using the voltage transformer by opening the isolating switch.