How to prevent the sealing problem of current transformer?
Feb 12, 2025| 1. Correct installation and assembly
Sealing gasket installation: When installing the current transformer, make sure the sealing gasket is installed correctly. The sealing gasket should be placed in a suitable position, such as between the connection surface of the housing cover and the body, around the inlet and outlet terminals, etc. Before installation, check the quality of the gasket to ensure that there is no damage, deformation or aging. During installation, pay attention to the flatness of the gasket to avoid wrinkles or twists. For example, for rubber sealing gaskets, some sealing grease can be applied appropriately during installation to enhance the sealing effect, but be careful not to apply too much sealing grease to avoid entering the transformer.
Shell connection tightening: For current transformers with shell connections, tighten the connection bolts according to the specified torque. Use appropriate tools, such as torque wrenches, to ensure that the tightening of the bolts is uniform. Overtightening may damage the sealing gasket or the housing, while undertightening will result in poor sealing. During the connection process, ensure that the connection surface of the housing is clean, flat, and free of debris or protrusions to ensure good sealing contact.
Sealing treatment of inlet and outlet terminals: The sealing of the inlet and outlet terminals is very important. When installing the terminals, use a sealing sleeve of qualified quality and ensure that the sealing sleeve fits tightly around the terminals and wires. For larger wires, a multi-layer sealing method can be used, such as wrapping with insulating tape first and then putting on the sealing sleeve. At the same time, after connecting the wires, check whether the sealing sleeve has signs of looseness or damage.
2. Regular inspection and maintenance
Appearance inspection: Regularly (such as quarterly or semi-annual) inspect the appearance of the current transformer, focusing on the sealing parts. Check whether the sealing gasket is aging, deformed, displaced, etc., check whether the connection parts of the shell are loose or have gaps, and whether the sealing sleeves of the inlet and outlet terminals are intact. If problems are found, timely measures should be taken to repair or replace them. For example, for a slightly deformed sealing gasket, you can try to adjust its position; for a severely aged gasket, it should be replaced in time.
Pressure and oil level monitoring (applicable to current transformers with pressure requirements or oil-immersed current transformers): For current transformers with internal pressure requirements (such as SF6 gas-insulated current transformers), the internal pressure should be monitored regularly. Record the changes in pressure values. When the pressure drops beyond the specified rate, check the sealing condition in time. For oil-immersed current transformers, check the oil level regularly and observe the reading of the oil level gauge. If the oil level drops abnormally, in addition to considering normal factors such as oil temperature changes, check whether there are sealing problems caused by oil leakage.
3. Operating environment control
Temperature control: Avoid the current transformer from being in an environment with drastic temperature changes for a long time. Temperature changes can cause the gas or liquid inside the transformer to expand or contract, increase the pressure of the sealing components, and may cause the seal to fail. For example, if the transformer installed outdoors may be exposed to direct sunlight and cause the temperature to be too high, shading measures such as installing a sunshade can be taken to reduce the impact of temperature on the seal.
Humidity control: Control the humidity of the operating environment to prevent moisture from eroding the sealing components. A high humidity environment may cause the sealing gasket to become damp and moldy, reducing its sealing performance. In a humid environment, dehumidification equipment, such as a dehumidifier, can be installed to control the ambient humidity within a reasonable range (such as not exceeding 70%).
Prevent external shock and vibration: The current transformer should be protected from external shock and vibration during operation, as these factors may cause the sealing components to loosen or be damaged. When choosing the installation location, try to avoid installing it in places that are prone to collision or vibration, such as near traffic arteries or areas where large mechanical equipment is running. If it cannot be avoided, take shock absorption and protection measures, such as installing shock-absorbing pads or guardrails.
4. Component quality control
Choose high-quality sealing materials: In the manufacturing and maintenance of current transformers, sealing materials with good quality, aging resistance, and temperature resistance should be selected. For example, for sealing gaskets, high-quality rubber materials can be selected, which have good elasticity and sealing properties, and can remain stable within a certain temperature and humidity range. For sealing sleeves, materials with good oil resistance and wear resistance can be selected to adapt to the working environment of the inlet and outlet terminals.
Strict component inspection: Before purchasing and installing sealing components, the components must be strictly inspected. Check whether the specifications and dimensions of the sealing materials meet the requirements and whether the sealing performance meets the standards. The sealing components can be tested for sealing properties by sampling, such as performing air pressure or hydraulic pressure tests on sealing gaskets to ensure that they can meet the sealing requirements of the current transformer.