Zero Sequence Current Transformer is also called protection current transformer. The requirement for this type of transformer is that the error does not exceed the specified range under specified conditions. The role of this type of transformer is to cut off the power supply in the event of a system fault short-circuit current. In the application process, due to the large short-circuit current, the core of the zero sequence transformer is saturated, which causes the excitation current of the Zero Sequence Current Transformer to increase, which causes the transmission error to increase. When the short-circuit current starts to have a DC component or the Zero Sequence Current Transformer core has residual magnetism, this error will be greatly aggravated.

In view of the saturation of the Zero Sequence Current Transformer during the construction process, the correct choice is required. There are three considerations for current transformers.

One: Use P type transformer, this type of transformer does not consider transient saturation, but considers the large steady-state short-circuit current through the transformer Z. The comprehensive protection system adopts appropriate parameters to prevent the transformer from transient saturation. This type of mutual inductance The transformer includes P type PR and PX, etc. The accuracy limit coefficient of the transformer is considered according to the composite error of a steady-state symmetrical current or the excitation inflection point. This type of transformer is currently widely used.

Two: TP type transformer (including TPS, TPX, TPY, TPZ type) when the short-circuit current has periodic components and non-periodic components, and keep the error within the specified transient working cycle peak conditions . This type of transformer significantly increases the size and cost of the transformer. Usually used in ultra-high voltage systems or large-capacity generators.

Three: TPE type transformer, this type of transformer considers the peak error under steady-state and transient working conditions at the same time, and outputs low-level analog or digital signals, which are characterized by low power consumption, fast response, long transmission distance, and unsaturation , Large dynamic range, wide frequency, no resonance. Such transformers include photoelectric transformers, air-core coil transformers, etc. These transformers are mostly used in smart power stations.