1: 2500 Current Sensor with DC Immunity (NRC05)
¨ 50/60 Hz,Single Phase,AC Current Sensor ¨ Dynamic Range from 5 to 20Amps ¨ Meets IEC62053-21 class 1 ¨ Meets IEC 60044-1 class 0.1 Phase error < 5' ¨ Immune to external AC magnetic field. Immune to DC current & DC magnetic field ¨ Very low temperature coefficient ¨ Meets UL class B (130ºC) thermal insulation system ¨ Meets UL 94V-0 ¨ AC isolation resistance: 4KV for 60s Resis DC component :≤±3%
- Product Introduction

Introduction
The DC Immune Current Transformer (CT) is a specialized device designed to accurately measure alternating current (AC) without being affected by DC components. This unique capability is crucial in applications where both AC and DC coexist, such as in renewable energy systems, electric vehicles, and industrial automation. The DC Immune CT utilizes advanced magnetic core materials and innovative design techniques to ensure high accuracy and reliability, making it an essential tool for monitoring and controlling electrical systems.
Description
- 50/60 Hz,Single Phase,AC Current Sensor
- Dynamic Range from 10 to 80Amps
- Meets IEC 60044-1/IEC61869-2 Class 0.1/0.2
- Immune to external AC magnetic field. Immune to DC current & DC magnetic field
- Very low temperature coefficient
- Meets UL class B (130ºC) thermal insulation system
- Meets UL 94V-0
- AC isolation resistance: 4KV for 60s
- Resistant to DC component :≤±3%
|
ELECTRIC SPECIFICAITON AT 25℃ |
||||||||||
|
Model number |
Turns Ratio |
Ipri4 |
Iout5 |
Iprimax6 |
Ioutmax7 |
Resistant to DC compoment |
Accuracy Class3 |
RL8 |
Weight |
Frequency range |
|
Amps |
mA |
Amps |
mA |
% |
Ohms |
(g) |
(Hz) |
|||
|
LO-ADC704 |
1:2500 |
10 |
4 |
80 |
32 |
≤±3% |
0.1/0.2 |
5-20 |
20 |
50-60 |
Note:
1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.
2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.
3.Accuracy class per IEC60044-1Table 11.
4.Ipri=Rated primary current.
5.Iout=Rated secondary current.
6.Iprimax=Sensed max primary current.
7.Loutmax=Sensed max secondary current.
8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following
equation RL=Vout*Nsec/Ipri
|
ABSOLUTE MAXIMUM RATINGS |
|
|
Operating free air temperature range |
-40ºC to 85ºC |
|
Storage temperature range |
-40ºC to 100ºC |
|
LEADS INFORMATION |
|
|
24AWG UL1569 Lead wires |
Leads length:150±5mm |
|
Stripped and tinned |
3+1/-0mm |
Mechanical specificaiton

Wuxi Liou Electronics Co LTD
We have many international advanced fully automatic production lines, mainly producing and developing new types of 1: 2500 Current Sensor with DC Immunity (NRC05). We have professional, fast and timely after-sales service, which frees users from worries and optimizes the return on investment. Welcome to visit our company!Hot Tags: high precision dc immune current transformer, China, manufacturers, customized, quotation, low price, made in China, Residual Current Transformer, Three Phase Current Transformer 1: 3000, Feadthrough residual current transformer, High Current Center Through Current Transformer, Lo-Spct-3000 Split Core Current Sensor, Monophase Ac Precision Miniature Current Transformer