
1: 2500 DC Immune Current Transducer
This transformer is used for high precision, small phase error requires current, power, power monitoring and measurement devices. It is suitable for single-phase or three-phase electronic energy meters.
- Product Introduction

Introduction
This DC immune transformer is used for high precision, small phase error requires current, power, power monitoring and measurement devices. It is suitable for single-phase or three-phase electronic energy meters. Our products are encapsulated in epoxy to ensure high insulation.
Applicatioin
- Renewable Energy: In solar and wind power systems for monitoring and controlling current flows, ensuring efficient energy conversion.
- Electric Vehicles: In charging stations and battery management systems to accurately measure charging and discharging currents.
- Power Generation and Distribution: For precise current measurement in substations and distribution networks, enhancing grid stability.
- Industrial Automation: In manufacturing facilities for real-time monitoring of equipment performance and energy consumption.
- Telecommunications: To ensure the reliability of power supplies in communication infrastructure, particularly in backup systems.
- Railway Systems: For monitoring current in traction power systems and ensuring efficient operation of electric trains.
Features
- 50/60 Hz,Single Phase,AC Current Sensor
- Dynamic Range from 5 to 120Amps
- Meets IEC 60044-1/IEC61869-2 Class 0.1/0.2
- Immune to external AC magnetic field. Immune to DC current & DC magnetic field
- Very low temperature coefficient
- Meets UL class B (130ºC) thermal insulation system
- Meets UL 94V-0
- AC isolation resistance: 4KV for 60s
- Resistant to DC component :≤±3%
|
ELECTRIC SPECIFICAITON AT 25℃ |
||||||||||
|
Model number |
Turns Ration |
Ipri4 |
Iout5 |
Iprimax6 |
Ioutmax7 |
Resistant to DC component |
Accuracy Class3 |
RL8 |
Magnetic shield |
Frequency range |
|
Amps |
mA |
Amps |
mA |
% |
|
Ohms |
Tesla |
(Hz) |
||
|
LO-ADC726DT |
1:2500 |
5 |
2 |
60 |
24 |
≤±3% |
0.1/0.2 |
5-20 |
300mT |
50-60 |
|
1:2000 |
5 |
2.5 |
60 |
30 |
||||||
|
1:2500 |
10 |
4 |
60 |
24 |
≤±3% |
|||||
|
1:2000 |
10 |
5 |
60 |
30 |
||||||
|
1:1000 |
10 |
10 |
60 |
60 |
||||||
|
1:2500 |
5 |
2 |
80 |
32 |
≤±3% |
|||||
|
1:2500 |
10 |
4 |
80 |
32 |
||||||
|
1:2500 |
10 |
4 |
100 |
40 |
||||||
|
1:2500 |
10 |
4 |
120 |
48 |
||||||
Note
1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.
2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.
3.Accuracy class per IEC60044-1Table 11.
4.Ipri=Rated primary current.
5.Iout=Rated secondary current.
6.Iprimax=Sensed max primary current.
7.Loutmax=Sensed max secondary current.
8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following
equation RL=Vout*Nsec/Ipri
Dimensions

Wuxi Liou Electronics Co Ltd
Advantages
Suitable for all kinds of currents.
High cost performance, environmental protection and pollution.
Small size, high precision and good consistency.
Excellent ratio error and accuracy.
Detailed installation in different situations
When installing a current transformer, it is mainly evaluated according to the configuration of the equipment. Under normal circumstances, there are several different situations.
1. Install the current transformer directly on the metal frame, such as the structure of the busbar;
Second, if the busbar passes directly through the floor or the wall, the current transformer is fixed with the most basic bolts, or the angle frame is used to make the rectangular frame, and then the current transformer is directly fixed on the frame.
Third, the current transformer is installed directly in the complete power distribution cabinet. For the current transformer of this type of installation, in fact, we do not need to install the body, only the key inspection wiring can be used.
What can we do?
Adhere to the concept of quality first
Standardizing work procedures as a means
Creating customer satisfaction
Continuous quality improvement as power
We believe that the success of 1: 2500 DC Immune Current Transducer has laid the foundation for our company's development and also opened up future-oriented development. We respond to customers' demands or complaints as soon as possible and pay attention to customer experience and satisfaction. Our company has a professional marketing team, superb technology, and high-quality service. Welcome new and old customers to our company to negotiate business.
Hot Tags: 1: 2500 dc immune current transducer, China, manufacturers, customized, quotation, low price, made in China, High Precision Zero Sequence Current Transformer, Split Core Type Current Transformer, Round Zero Sequence Current Transformer, 100mA AC Current Transformer, High Frequency Current Sensor, Split Core Closed Loop Hall Effect Current Sensors






