20A High Voltage Current Transformer for Energy Meter

20A High Voltage Current Transformer for Energy Meter

Our products have high performance, high magnetic permeability, low coercivity, high saturation magnetic induction, high stability, low loss and high cost performance.

  • Product Introduction
To create more value for customers is our business philosophy; customer growing is our working chase for zero phase mini current transformer, Ground Fault Residual Current, Split Residual Current Transformer. We have a dedicated and aggressive sales team, and many branches, catering to our main customers. In his way, We can enrich our life style and promote a better living environment for the global community. We take our dreams as the driving force and use the application policy as the benchmark to implement all aspects of corporate operations, and actively share joy and touch with global customers.

67

68


Description

¨   50/60 Hz,Single Phase,AC Current Sensor

¨   Dynamic Range from 0.5 to 120Amps

¨   Meets IEC62053-21 class 1

¨   Meets IEC 60044-1 class 0.1 Phase error < 5'

¨   Immune to external AC magnetic field. Immune to DC current & DC magnetic field

¨   Very low temperature coefficient

¨   Meets UL class B (130℃) thermal insulation system

¨   Meets UL 94V-0

¨AC isolation resistance: 4KV for 60s






Application

•   Electricity meter

   Recording

   Power monitoring

   Energy management

   Alternative energy monitoring


ELECTRIC SPECIFICAITON AT 25

Model number

Turns Ration

Ipri4

Iout5

Iprimax6

Ioutmax7

RS

Accuracy

Class3

RL8

Weight

Frequency

range

Amps

mA

Amps

mA

Ohms


Ohms

(g)

(Hz)

LO-ADC0001

1:2500

10

4

120

50


0.1

25


50-60


Note:

1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.

2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.

3.Accuracy class per IEC60044-1Table 11.

4.Ipri=Rated primary current.

5.Iout=Rated secondary current.

6.Iprimax=Sensed max primary current.

7.Loutmax=Sensed max secondary current.

8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following

equation RL=Vout*Nsec/Ipri


Schematic diagram:

4

Dimensions:

LO-ADC0001 DIMENSIONS

We are a technology-oriented large-scale 20A High Voltage Current Transformer for Energy Meter company integrating R&D, operation and service. With the rapid development of the Chinese economy and the improved level of industry, we expect our company's activities to be further developed in the near future. The management team of our company has a profound professional technical background and is constantly pushing forward the development of related applications.

Hot Tags: High Precision current Transformer with primary bus bar, China, manufacturers, customized, quotation, low price, made in China, Precision AC Current Transformer, Ground Fault Protection Current Transformer, Automobile Antenna Vehicle, Split Core Type Current Transformer, High Frequency Current Sensor, Class 0 1 Three Phase Current Transformer

[[ProKeywords]]
Send Inquiry