48V/10.4A AC DC Switch Power Supply Switching Power Supply
The electronic current transformer for measurement is used to convert the current of the corresponding circuit to the electronic current transformer of the measuring instrument
- Product Introduction

Introduciton
The electronic current transformer for measurement is used to convert the current of the corresponding circuit to the electronic current transformer of the measuring instrument, the integral meter and the like when the power system is in normal operation.
Description
50/60 Hz,Single Phase,AC Current Sensor
Dynamic Range from 0.1 to 20Amps
Meets IEC62053-21 class 1
Meets IEC 60044-1 class 0.1 Phase error < 5'
Very low temperature coefficient
Meets UL class B (130℃) thermal insulation system
Meets UL 94V-0
AC isolation resistance: 4KV for 60s
Application
Digital electricity meter
Recording
Power monitoring
Energy management
Alternative energy monitoring
ELECTRIC SPECIFICAITON AT 25℃ | ||||||||||
Model number | Turns Ration | Ipri4 | Iout5 | Iprimax6 | Ioutmax7 | RS | Accuracy Class3 | RL8 | Weight | Frequency range |
Amps | mA | Amps | mA | Ohms | Ohms | (g) | (Hz) | |||
LO-DM0002 | 1:2000 | 5 | 2.5 | 20 | 10 | 0.1 | 100 | 50-60 | ||
Note:
1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.
2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.
3.Accuracy class per IEC60044-1Table 11.
4.Ipri=Rated primary current.
5.Iout=Rated secondary current.
6.Iprimax=Sensed max primary current.
7.Loutmax=Sensed max secondary current.
8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following
equation RL=Vout*Nsec/Ipri
ABSOLUTE MAXIMUM RATINGS | |
Operating free air temperature range | -40℃ to 85℃ |
Storage temperature range | -40℃ to 100℃ |
LEADS INFORMATION | |
UL1007 22Awg wire black & red | 75mm±5.0mm |
Terminal block | 2.5mm terminal |

Mechanical Specifications

Advantages
Good insulation performance and beautiful appearance. It has the characteristics of high sensitivity, good linearity, reliable operation and convenient installation. Its performance is better than the general zero-sequence current transformer, which is more widely used. It not only adapts to electromagnetic relay protection, but also adapts to electronic and microcomputer protection devices. Users can effectively ground or neutral according to the operation mode of the system. For the difference of non-effective grounding, select the appropriate zero-sequence current transformer.
QC
Liou has a strict quality control system. From materials to finished products. We conducted an inductive test on each core. Then choose the right core to make the transformer. Then we conducted DC, current, and high voltage tests. After approval, we check the appearance and parameters of the inspection and package the goods.
Hot Tags: 1: 2000 High Accuracy Current Transformer rectangle hole, China, manufacturers, customized, quotation, low price, made in China, Zero Phase Current Transformer, High Accuracy CT Digital Meter Current Sensor, DC Residual Current Sensor, Split core DC current sensors, Feadthrough residual current transformer, Zero flux current transformer