50A 333mv Split Core Current Transformers with Customized Connector

50A 333mv Split Core Current Transformers with Customized Connector

A current transformer is an instrument transformer that is used with a measurement or protection device where the secondary current is proportional to the primary current

  • Product Introduction
Sticking for the perception of 'Creating products of top quality and producing friends with people today from all around the world', we constantly place the desire of shoppers to start with for Split Core Closed Loop Hall Effect Current Sensors, Forward Topology Planar Transformer 180W, Residual Current Transformer Current factory. We are sure our profitable experience in tool generation will gain customer's trust, Wish to co-operate and co-create a far better foreseeable future with you! Our company insists on the tenet of striving for survival with quality and reputation as the foundation, and the service market is also gradually facing international.

55

 

Description

  • 47-5000 Hz,Single Phase,AC Current Sensor
  • Rated up to 50A
  • Dynamic Range from 10 to 50Amps
  • Linearity ≤0.1 Phase error < 15'
  • Very low temperature coefficient
  • Meets UL class B (130℃) thermal insulation system
  • Meets UL 94V-0
  • AC isolation resistance: 3.75KV for 60s
  • High current density

 

Application

• Switching power supplies

• Motor controls

• Power monitoring

• Energy management

• Alternative energy monitoring

 

ELECTRIC SPECIFICAITON AT 25

Model number

Turns Ration

Ipri1

Iout2

E-T3

RS

Linearity

LS4

Weight

Frequency

range

Amps

mA

V-uS

Ohms(Max)

 

H(Min)

(g)

(Hz)

LO-HF4001

1:1200

50

42

3000

40

≤0.1

10

20

47-5K

 

 

 

 

 

 

 

Note:

1.Ipri=Rated primary current.

2.Iout=Rated secondary current.

3.E-T is at Bi-Polar Only

4.Ls=Secondary inductance

 

Terminating resistor options

Ipri(Amps)

Terminating Resistor

E0

10

80

0.667

20

40

0.667

50

16

0.667

 

E-T=(E0*1/f)/2(Bi-Polar Only) E0=IP*(Rb/Tr)

E0=Output V Ip=Pri.Current Tr=Turns Ratio f=frequency Rb=Term Res

 

ABSOLUTE MAXIMUM RATINGS

Operating free air temperature range

-40℃ to 85℃

Storage temperature range

-40℃ to 100℃

SOLDERING INFORMATION

Peak wave solder temperature

300℃ for 10Seconds

Pin finish

Tin

 

Mechanical Specifications:

 

LO-HF4001 DIMENSIONS

 

Schematic diagram:

 

88

 

Wuxi Liou Electronics Co Ltd

Sticking towards the theory of 'Super Good quality, Satisfactory service', We are striving to become a superb business enterprise partner of you for 50A 333mv Split Core Current Transformers with Customized Connector. We hope to improve the innovation mechanism and organizational structure through continuing to strengthen the sustainable development path, and integrating internal and external resources from a strategic height. The development of technology and its large-scale, low-cost applications provide us with opportunities to reduce costs, while satisfying customers' special needs to the greatest extent.

Hot Tags: 50a current transformer, China, manufacturers, customized, quotation, low price, made in China, Zero Sequence Ground Fault Current Transformer, Split Core DC Current Transducer, 200A 5A Center Through CT, Clamp On Current Transformer, Lo-Spct-3000 Split Core Current Sensor, Ground Fault Center Through CT

[[ProKeywords]]
Send Inquiry