B9 Closed Loop Hall Effect Current Sensor/Transmitter PCB Current Transducer

B9 Closed Loop Hall Effect Current Sensor/Transmitter PCB Current Transducer

In the electrical systems always exists the possibility of having shutdowns due to over currents or short circuits produced by operation mistakes,ambient conditions,lack of maintenance or atmospheric discharges.

  • Product Introduction
Our company mainly operates High Precision Zero Sequence Current Transformer, Digital Split core current sensor Leakage Current, Open Residual Current Transformer and other business sectors, with comprehensive product series, reliable quality, and excellent performance, achieving core technological breakthroughs and possessing core component manufacturing capabilities. We are based on honesty cherishing the hard-won honors, and sincerely thank friends and customers from all walks of life for their long-term care and support. You are sincerely welcome to visit our company to talk business face to face with each other and establish long-term co-operation with us! We have faith in 'building a brand with quality and winning the market with integrity', and we always aim at customer satisfaction, constantly innovating technology, and improving product service quality.

Round type leakage detection residual current transformer

 

S/N: LO-ZRCT-XX

 

Product overview:

 

The LO-ZRCT-XX series residual current transformers are primarily used in low-voltage distribution systems such as 380V and 660V, or in densely packed drawer cabinets, to continuously monitor and detect residual currents at installation nodes in corresponding circuits. The outer shell of this series is made from environmentally friendly flame-retardant ABS engineering plastic, and it uses high magnetic permeability nanocrystalline soft magnetic material. Combined with a reasonable structural design and rigorous production processes, the product features high precision, good balance performance, small size, high insulation strength, strong impact resistance, and easy installation, making it reliable and stable for indoor use.

Additionally, the structural design incorporates customer feedback, with the fixing feet designed to be retractable into corresponding slots before transport and installation. This prevents damage to the fixing feet before installation, reducing the risk of product failure, and also helps lower packaging and transportation costs. This series includes 11 different models, suitable for monitoring residual currents in cable circuits or copper busbar circuits, with a minimum detectable leakage current of less than 5mA and accuracy meeting or exceeding the national standard GB14287.2. The balance characteristics can be customized according to usage requirements. The color of the product casing can be customized to meet different color scheme requirements specified by customers.

 

Features:

 

  • Resin casting process, excellent waterproof and moisture-proof performance
  • It has strong overload capability and can be overloaded 50 times the rated current for a long time if necessary.
  • Excellent balance characteristics, small size products meet the detector alarm threshold requirement of 20mA
  • High precision: precision level 0.5/1.0/3, optional compact design, small size

 

Structure:

 

678

 

S/N

Name

Main features

1

Secondary

terminal block

For output signal connection

2

Fixing tube

Made of brass or ABS plastic, used to connect the two parts of the transformer housing during assembly.

3

PCB for terminal connector

Hidden beneath the terminal block, to connect the output signal wires terminals and clamping diode

4

Clamping diode

According to the customer's technical specifications, the output signal is clamped to the required voltage

5

Insulation layers of core

The structure used to protect the iron core and prevent the enamel-coated wires of the winding from being damaged.

6

Core

Highly permeable nanocrystalline soft magnetic materials

7

Fixing part

Produced from flame-retardant ABS engineering plastic, it is rotated out from the enclosure slot during installation to secure the product.

8

Secondary winding

Made of oxygen-free copper material, directly welded with polyurethane paint film, temperature resistant up to 155 degrees Celsius

9

Winding insulation

Polyester film/PVC film/crepe paper, etc., used to protect enameled wires from damage

10

Shield

Made of high magnetic permeability silicon steel or other magnetic permeability materials to ensure excellent balance characteristics

11

Enclosure

Flame-retardant ABS plastic or PC/ABS alloy plastic, with high temperature resistance, high strength and good flame-retardant properties

 

Normal use and installation conditions:

 

  • Installation location: indoor/outdoor. Ambient temperature -40℃ ~ +45℃
  • It is recommended that the relative humidity of the environment should not be greater than 80%
  • The altitude does not exceed 3000m
  • Atmospheric conditions: There are no seriously polluted, corrosive and explosive media in the atmosphere
  • An environment without significant frequent vibration and shock. Storage temperature :-20℃ ~ +75℃

 

Balance performance:

 

P/N

Main circuit rated operating current

Test current

Conductor diameter

Conductor insulation thickness

Unbalance current

LO-ZRCT-30

0≤In≤63A

63A

4mm

0.5mm

≤2mA@63A

LO-ZRCT-46

0≤In≤100A

100A

6mm

1.0mm

≤5mA@315A

LO-ZRCT-65

0≤In≤250A

250A

10mm

1.5mm

≤5mA@315A

LO-ZRCT-80

0≤In≤315A

315A

10mm

1.5mm

≤10mA@630A

LO-ZRCT-100

0≤In≤630A

630A

14mm

2.0mm

≤20mA@630A

LO-ZRCT-120

0≤In≤1000A

1000A

20mm

2.0mm

≤20mA@1000A

 

Dimensions:

87

 

Model specifications

Main circuit current (A)

Aperture

(mm)

Overall dimensions (mm)

Dimensions (mm)

L

W

H

D1

D2

W

LO-ZRCT-30

≤63A

30

65

32

75

67.5

75.5

6

LO-ZRCT-46

≤100A

46

85

32

94

88.5

100.5

6

LO-ZRCT-65

≤250A

65

108

32

120

108.5

122

6

LO-ZRCT-80

≤400A

80

128

36

140

134

144

6

LO-ZRCT-100

≤630A

100

150

36

162

152

172

6

LO-ZRCT-120

≤1000A

120

172

36

184

177

197

6

 

General technical specs:

 

Technical Spec

Electrical specs

Rated primary current

1000mA

5A

5A

10A

10A

Rated secondary current

0.5mA

2.5mA

5mA

5mA

10mA

Rated continuous thermal current

2000mA

10A

10A

50A

50A

Operating frequency

50-60Hz

Rated Accuracy class

Equal or above Class 0.5

Operating voltage

<=660V

Flame retardant class

UL94V-0

Insulation resistance

>= 1M Ohms @500VDC

Dielectric strength

AC3KV/2mA/60s/50Hz

Thermal Class

Class B

 

When the corresponding AC current passes the residual current transformer, the output sampling voltage should meet the requirements listed in the table below

 

1

R=1000Ω C=0.022uF Current source frequency:50-60Hz, accuracy class better than 0.1%, the voltage meter accuracy class of mV testing range is better than 0.1%

 

Detection current value(mA)

Current range

(mA)

Load resistor

Testing terminals

Sampling voltage range

(mV)

50

49.75-50.25

1000Ω/0.022uF

S1-S2

24.64-25.64

200

199-201

97.18-101.14

500

498-502

243.01-253.01

800

796-804

388.7-404.7

1000

995-1005

486.25-506.26

 

WuXi Liou Electronics Co.,Ltd

 

 

 

 

We are also focusing on improving the stuff management and QC system so that we could keep great advantage in the fiercely-competitive business for B9 Closed Loop Hall Effect Current Sensor/Transmitter PCB Current Transducer. To benefit from our strong OEM/ODM capabilities and considerate services, please contact us today. We use advanced equipment and instruments to strictly manufacture and test products, pay close attention to the demands of users, and constantly innovate products and services.

Hot Tags: residual current sensor, China, manufacturers, customized, quotation, low price, made in China, High Frequency Current Transformer, AC Current Transformer Current, Zero Phase Current Sensor, Single phase ac current transformer, DC Immune Current Transducer 1 2000, 1 200 High Frequency Current Transformer