Closed Loop Hall Effect Current Sensor Variable-Frequency Drive Measurement
Hall-effect current sensors have high quality and reliable current sensors in an industry standard package.The sensor also provides fast response,galvanic isolation and high precision measurement of DC and high frequency AC current.
- Product Introduction

Hall effect current sensor for leakage current detection
P/N: LO-HALL-CT0100
Introduction
Closed-loop sensors measure AC and DC currents and provide electrical isolation. They offer fast response, high linearity, and low emperature drift. The current output of the closed-loop sensor is relatively immune to electrical noise. The Closed- Loop sensor is sometimes called a'Zero-Flux'sensor because its Hall-Effect sensor feeds back an opposing current into a secondary coil, wound on the magnetic core to zero the flux produced in the magnetic core by the primary current. Closed-loop sensors are often the sensor of choice when high accuracy is essential.
Features:
-
Wide frequency range
-
Good overall accuracy
-
Fast response time
-
Low temperature drift
-
Excellent linearity
-
No insertion loss
Application:
|
AC inverters |
DC motor drive static converters |
|
Communication power supplies |
Uninterruptible power supplies |
|
Switch power supplies |
Welder power applications |
|
UPS power supply |
New energy |
|
Smart transportation |
Chemicals and Machinery |
Electric specifications:
|
P/N |
LO-HALL-CT0100 700mA/7V |
|
|
In |
Rated Input(AC) |
700mA |
|
IP |
Testing range |
0.01-700mA |
|
RM |
Testing resistor |
>10KΩ |
|
VM |
Rated Output(AC) |
7V |
|
KN |
Turns Ratio |
----- |
|
X |
Accuracy(Ta=+25℃) |
5% of standard values |
|
VC |
Power Voltage |
±12VDC/±15VDC |
|
VI |
Dielectric voltage |
AC2.5KVA,50Hz,60S |
|
Vaff |
Offset voltage@25℃ |
When primary current is In=0, <±1mV |
|
Td |
Temperature drift(-40℃-+85℃) |
0.05%/℃ of VM |
|
L |
Linearity |
<0.02% |
|
di/dt |
----- |
|
|
F |
Frequency range |
50HZ(400HZ) |
|
Ta |
Operation temperature |
-40℃-+85℃ |
|
Ts |
Storage temperature |
-40℃-+100℃ |
|
Ic |
Power loss |
10mA |
|
Rs |
Secondary resistance@25℃ |
------ |
|
RN |
Primary resistance@25℃ |
------ |
|
W |
Weight |
730g |
Schematic Diagram:

Mechanical Specifications:

Wuxi Liou Electronics Co Ltd
We'll make each hard work to become excellent and excellent, and speed up our measures for Closed Loop Hall Effect Current Sensor Variable-Frequency Drive Measurement. We have accumulated rich experience in the international market and can provide excellent products and services for global customers. After several years of hard work and development, our company now has a certain scale and strength, and has a skilled team, with excellent service quality and professional technical service, to provide customers with more cutting-edge products.
Hot Tags: Closed Loop Hall Effect Sensors used for residual leakage current, China, manufacturers, customized, quotation, low price, made in China, High Frequency Current Transforemr 1: 1000, Power Current Transformer, 100mA AC Current Transformer, Zero Phase Current Transformers, Class 0.1 Three Phase Current Transformer, Ground Fault Residual Current