Customized Waterproof High Voltage Low Current Transformer

Customized Waterproof High Voltage Low Current Transformer

Our products have high performance, high magnetic permeability, low coercivity, high saturation magnetic induction, high stability, low loss and high cost performance.

  • Product Introduction
Our primary target will be to provide our clients a serious and responsible small business relationship, supplying personalized attention to all of them for Current Transformer Clamp-on, Residual Current Transformer Current factory, Zero Sequence Current Transformers. Through years of development, we have laid a solid industry foundation and formed a strong sales network that our products have spread all over the country. We hope that our employees can realize their personal value through self-struggle and realize the common development of company employees through teamwork. Creating value for you is the goal we always pursue. We will continue to improve and optimize, and establish a distinctive system of production, sales and service in order to better serve our customers.

67

68


Description

¨   50/60 Hz,Single Phase,AC Current Sensor

¨   Dynamic Range from 0.5 to 120Amps

¨   Meets IEC62053-21 class 1

¨   Meets IEC 60044-1 class 0.1 Phase error < 5'

¨   Immune to external AC magnetic field. Immune to DC current & DC magnetic field

¨   Very low temperature coefficient

¨   Meets UL class B (130℃) thermal insulation system

¨   Meets UL 94V-0

¨AC isolation resistance: 4KV for 60s






Application

•   Electricity meter

   Recording

   Power monitoring

   Energy management

   Alternative energy monitoring


ELECTRIC SPECIFICAITON AT 25

Model number

Turns Ration

Ipri4

Iout5

Iprimax6

Ioutmax7

RS

Accuracy

Class3

RL8

Weight

Frequency

range

Amps

mA

Amps

mA

Ohms


Ohms

(g)

(Hz)

LO-ADC0001

1:2500

10

4

120

50


0.1

25


50-60


Note:

1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.

2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.

3.Accuracy class per IEC60044-1Table 11.

4.Ipri=Rated primary current.

5.Iout=Rated secondary current.

6.Iprimax=Sensed max primary current.

7.Loutmax=Sensed max secondary current.

8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following

equation RL=Vout*Nsec/Ipri


Schematic diagram:

4

Dimensions:

LO-ADC0001 DIMENSIONS

The company now has a professional Customized Waterproof High Voltage Low Current Transformer production plant with complete inventory supply, timely delivery, considerate after-sales service, and reasonable prices. We have implemented a strict and complete quality control system, which ensures that each product can meet quality requirements of customers. We have our possess manufacturing facility and sourcing place of work.

Hot Tags: High Precision current Transformer with primary bus bar, China, manufacturers, customized, quotation, low price, made in China, Open Residual Current Transformer, Residual Current Transformer Current factory, High Precision Current Transformer, Split core current transformer with high accuracy, Residual Current Transformer High Current factory, Current Transformer Clamp on