Dasn-242 Series Three Phase Current Transformer 60-250A for Current Sensor CT

Dasn-242 Series Three Phase Current Transformer 60-250A for Current Sensor CT

The CT series current transformers are plug-in primary types with a secondary loop wound around a directional electrical steel core.It is often referred to as a meter transformer for measuring current.

  • Product Introduction
With the joint efforts of our R&D department, marketing department and after-sales service department, our Residual Current Sensor, Rectange Split Core Current Sensor factory, High Frequency Current Transforemr 1: 1000 can achieve a perfect combination of technology and design, thereby providing quality products to customers all over the world. Abiding by our motto of 'Hold well the quality and services, Customers Satisfaction', So we provide our clients with high quality products and excellent service. Nowadays our products sell all over the domestic and abroad thanks for the regular and new customers support. Besides, all of our solutions have been strictly inspected before shipment. Through our respective businesses, we give full play to our respective capabilities to create high-value products and services that exceed customer expectations.

Introduction

The CT series current transformers are plug-in primary types with a secondary loop wound around a directional electrical steel core.It is often referred to as a meter transformer for measuring current. The current transformer produces a reduced current that is precisely proportional to the current in the circuit and can be easily connected to the measuring and recording instrument.


CT Series Current Transformers(001)


Application

Our products can sense overload current, ground fault detection, and current signal measurement.

Function

The current transformer is divided into a current transformer for measurement and a current transformer for protection; the function of the current transformer for measurement is used to measure (charge) and measure the current of the operating device; the current transformer for protection mainly and the relay device Cooperate, when the line is short-circuit overload and other faults, provide a signal to the relay device to cut off the fault circuit to protect the safety of the power supply system.

The causes and solutions of the following six faults in current transformers

1. When it is found that the current transformer has a secondary open circuit, it is necessary to distinguish the occurrence point of the fault, and the different phases of the switch, which will affect the entire protection, and report and schedule the situation, which may occur. The situation of misoperation is directly lifted;

2.It is best to reduce the load current once as much as possible. If the damage of the current transformer is serious, the load should be transferred and directly powered off for processing and inspection;

3.On the nearest test terminal, the current transformer is subjected to a secondary short circuit, and then the open circuit point is checked, and a relatively short wiring is used;

4. If there is a spark in the process of short circuit, it means that the short circuit is effective, and also indicates that the fault point is in the circuit of the short contact point;

5. Conversely, if there is no spark in the short circuit process, it means that the short circuit has no effect, and the fault point should not be in the loop;

6. Transfer the secondary short-circuit operation of the current transformer. It is best to perform power failure and check. When the current transformer is in secondary switch, it must use insulated tools with good insulation effect. Related tools such as gloves.

123456

QQ图片20200716135417_meitu_1

We are wholeheartedly committed to providing users with more competitive Dasn-242 Series Three Phase Current Transformer 60-250A for Current Sensor CT products and solutions. With the acceleration of the process of global economic integration, our company is taking the enterprise spirit of 'global vision, open thinking' and the work style of 'honesty, dedication and innovation' and through excellent actions, fine management and towards the road of diversification and internationalization. With enterprising thinking and challenging spirit, we will continue to create more advanced, more efficient and more perfect products, leading us to a brighter future.

Hot Tags: ct series current transformers, China, manufacturers, customized, quotation, low price, made in China, Monophase Ac Precision Miniature Current Transformer, Planar Transformer 28 2V Lo Plt8088 008, Open Circuit Current Transformer, Ground Fault Protection Current Transformer, Flexible Toroidal Split Core Current Transformer, Split Core Current Sensor