Dp-23 200/5A Split CT Open Type Single Phase Current Transformer
Split core AC current sensors have different hole sizes and current ratings to suit any application. Split core models are perfect for retrofits. Output is fixed at the industry standard.
- Product Introduction
Introduction
Split core AC current sensors have different hole sizes and current ratings to suit any application. Split core models are perfect for retrofits. Output is fixed at the industry standard.
Features
• High accuracy at 10-130% of rated current
• AC isolation resistance: 3KV for 60s
• Swing open for ease of installation
• Double secured latches per side and keying holes
• Rigid housing case with UL® 94V-0 durable plastic
• Safety standard: IEC/EN60044-1
• Nominal phase angle error and
Nominal linearity error: Conform IEC61869-2
ConformIEC60044-1
•Max.operation voltage: AC600V
Specificaiton
Item | Specificaiton |
Inputs | |
Frequency range 50-60Hz | |
Accuracy range 10-130% of rated current | |
Outputs | |
output at rated current 2mA-200mA | |
Enviromental | |
Operaiton temperature range -10°C to +60°C (+14°F to +140°F) | |
Storage temperature range -20°C to +85°C (+4°F to +185°F) | |
Lead length 70 ft black/white twisted pair wire leads-22 AWG | |
Certifications RoHS | |
Mechanical Specificaitons

Part Number | Description | A | B | C | D | E | ΦF | Primary Rated | Weight |
g | |||||||||
LO-SP3010 | CT 1:3000, 0.5% accuracy | 40.5 | 24.6 | 22 | 26 | 14.5 | 10 | 5, 15, 30, 50, 75,80 | |
LO-SP3016 | CT 1:3000, 0.5% accuracy | 44 | 27 | 29 | 31 | 19 | 16 | 50, 70, 100, 120 | |
LO-SP3024 | CT 1:3000, 0.5% accuracy | 75 | 46 | 45 | 35 | 19.5 | 24 | 100, 150, 200, 300 | |
LO-SP3036 | CT 1:3000, 0.5% accuracy | 91.6 | 58 | 57.4 | 40.9 | 22.8 | 36 | 300, 400, 500, 600 |
Installation

Application
● Data logging ● Recording ● Power monitoring | ● Energy management ● Alternative energy monitoring |
With our leading technology at the same time as our spirit of innovation, mutual cooperation, benefits and advancement, we will build a prosperous future with each other with your esteemed firm for Dp-23 200/5A Split CT Open Type Single Phase Current Transformer. Our team is united, pragmatic and forward-thinking, and our development is inextricably linked with the care and accompaniment of all clients and partners. Just like our customers all over the world, our team also has an international mindset and can provide thoughtful service to all customers.Hot Tags: single phase split core ct, China, manufacturers, customized, quotation, low price, made in China, Three Phase Current Transformer 1: 2000, Ac Precision Miniature Current Transformer, Ground Fault Residual Current, Zero Phase Current Transformers, Dc Current Transformer, Round Zero Sequence Current Transformer