Lzzbj9-10 10kv 200/5A Current Transformer High Voltage Low Current Transformer

Lzzbj9-10 10kv 200/5A Current Transformer High Voltage Low Current Transformer

Our products have high performance, high magnetic permeability, low coercivity, high saturation magnetic induction, high stability, low loss and high cost performance.

  • Product Introduction
As a qualified supplier, we have the ability to provide you with the best and most suitable products. If you do not meet the requirements, you can return or exchange the 60A: 5A Current Transformer Lo-Mc30I, Disposable 3-layer Mask factory, Single phase ac current transformer until you are satisfied. We will continue to carry forward the enterprise spirit of "integrity, teamwork, innovation, responsibility". As a socially responsible corporate citizen, we always focus on the consumer, and through scientific and technological innovation, we achieve low energy consumption production.

67

68


Description

¨   50/60 Hz,Single Phase,AC Current Sensor

¨   Dynamic Range from 0.5 to 120Amps

¨   Meets IEC62053-21 class 1

¨   Meets IEC 60044-1 class 0.1 Phase error < 5'

¨   Immune to external AC magnetic field. Immune to DC current & DC magnetic field

¨   Very low temperature coefficient

¨   Meets UL class B (130℃) thermal insulation system

¨   Meets UL 94V-0

¨AC isolation resistance: 4KV for 60s






Application

•   Electricity meter

   Recording

   Power monitoring

   Energy management

   Alternative energy monitoring


ELECTRIC SPECIFICAITON AT 25

Model number

Turns Ration

Ipri4

Iout5

Iprimax6

Ioutmax7

RS

Accuracy

Class3

RL8

Weight

Frequency

range

Amps

mA

Amps

mA

Ohms


Ohms

(g)

(Hz)

LO-ADC0001

1:2500

10

4

120

50


0.1

25


50-60


Note:

1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.

2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.

3.Accuracy class per IEC60044-1Table 11.

4.Ipri=Rated primary current.

5.Iout=Rated secondary current.

6.Iprimax=Sensed max primary current.

7.Loutmax=Sensed max secondary current.

8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following

equation RL=Vout*Nsec/Ipri


Schematic diagram:

4

Dimensions:

LO-ADC0001 DIMENSIONS

We provide customers with high-quality, high-tech, and high-profile Lzzbj9-10 10kv 200/5A Current Transformer High Voltage Low Current Transformer, hoping to continuously improve our reputation. With the rapid development since its inception our company has served to a great majority of customers through continuous innovation philosophy and pre-market awareness. Relying on the domestic and foreign markets, our company actively carries out product development and research. We have formed a virtuous circle of research and development, reserve generation and production generation in product research and development.

Hot Tags: High Precision current Transformer with primary bus bar, China, manufacturers, customized, quotation, low price, made in China, Antennas For Keyless Entry System, ZCT Zero phase current transformer, Toroidal Current Transformer, Zero Phase Current Sensor, General Electric Current Transformer, 1 200 High Frequency Current Transformer