Manufacturer Electrical Power Alternating Current High Voltage Transformer

Manufacturer Electrical Power Alternating Current High Voltage Transformer

Our products have high performance, high magnetic permeability, low coercivity, high saturation magnetic induction, high stability, low loss and high cost performance.

  • Product Introduction
Our items are exported around the world, enjoying a great popularity among the customers for Residual Current Transformer Current, Ac Current Transformer, 200A: 5A Center Through CT Lo-Mc30I. We professionally supplies customers with our main products And our business is not only the 'buy' and 'sell', but also focus on more. Using some knowledge and thinking methods for reference can guide us into the future. We actively introduce and train elite talents, create opportunities for the best talents, and allow them to grow continuously to create the company's long-term development. We abide by the corporate spirit of integrity and innovation, relying on strong R&D capabilities, efficient manufacturing, stable quality and thoughtful service to meet the needs of customers at home and abroad.

67

68


Description

¨   50/60 Hz,Single Phase,AC Current Sensor

¨   Dynamic Range from 0.5 to 120Amps

¨   Meets IEC62053-21 class 1

¨   Meets IEC 60044-1 class 0.1 Phase error < 5'

¨   Immune to external AC magnetic field. Immune to DC current & DC magnetic field

¨   Very low temperature coefficient

¨   Meets UL class B (130℃) thermal insulation system

¨   Meets UL 94V-0

¨AC isolation resistance: 4KV for 60s






Application

•   Electricity meter

   Recording

   Power monitoring

   Energy management

   Alternative energy monitoring


ELECTRIC SPECIFICAITON AT 25

Model number

Turns Ration

Ipri4

Iout5

Iprimax6

Ioutmax7

RS

Accuracy

Class3

RL8

Weight

Frequency

range

Amps

mA

Amps

mA

Ohms


Ohms

(g)

(Hz)

LO-ADC0001

1:2500

10

4

120

50


0.1

25


50-60


Note:

1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.

2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.

3.Accuracy class per IEC60044-1Table 11.

4.Ipri=Rated primary current.

5.Iout=Rated secondary current.

6.Iprimax=Sensed max primary current.

7.Loutmax=Sensed max secondary current.

8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following

equation RL=Vout*Nsec/Ipri


Schematic diagram:

4

Dimensions:

LO-ADC0001 DIMENSIONS

Our Manufacturer Electrical Power Alternating Current High Voltage Transformer is produced by advanced technology and world-class manufacturing capabilities so that it is of high quality and widely used. The company has advanced equipment, strong technical force, reliable reputation, good service and flexible business operation. In a complex market environment, while strictly controlling quality, we do not forget to improve the technical level and seek new innovation breakthroughs.

Hot Tags: High Precision current Transformer with primary bus bar, China, manufacturers, customized, quotation, low price, made in China, Core Balanced Current Transformers, zct zero sequence Current transformer, Antenna Used For Automobile, Current Transformer PCB CT, Split Core Hall Effect Current Sensor, DC Immune Current Transducer 1 2000

[[ProKeywords]]
Send Inquiry