Portable Electrical Current Transformer CT PT Vt Test Instrument Voltage Testing with High Accuracy 0.1%

Portable Electrical Current Transformer CT PT Vt Test Instrument Voltage Testing with High Accuracy 0.1%

Current transformers are subject to variable current and electrical isolation. It is a sensor for obtaining electrical primary loop current information in secondary equipment such as measuring instruments and relay protection in the power system.

  • Product Introduction
Our advantages are reduced prices, dynamic product sales workforce, specialized QC, solid factories, superior quality services for Ac Precision Miniature Current Transformer, General Used Current Transformer, Zero-Flux DC Current Transformer. We also have stable cooperation with several international trading companies. In terms of product services, we have launched a product quality assurance commitment, advocating "advanced service" and "full-process service".

45


Description

¨   50/60 Hz,Single Phase,AC Current Sensor

¨   Dynamic Range from 0.1 to 10Amps

¨   Meets IEC62053-21 class 1

¨   Meets IEC 60044-1 class 0.1 Phase error < 5'

¨   Very low temperature coefficient

¨   Meets UL class B (130℃) thermal insulation system

¨   Meets UL 94V-0

¨   AC isolation resistance: 4KV for 60s



Application

  • Digital electricity meter

  • Recording

  • Power monitoring

  • Energy management

  • Alternative energy monitoring



ELECTRIC SPECIFICAITON AT 25℃

Model number

Turns Ration

Ipri4

Iout5

Iprimax6

Ioutmax7

RS

Accuracy

Class3

RL8

Weight

Frequency

range

Amps

mA

Amps

mA

Ohms


Ohms

(g)

(Hz)

LO-DM0001

1:1000

2

2

10

10

20

0.1

100


50-60

Note:

1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.

2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.

3.Accuracy class per IEC60044-1Table 11.

4.Ipri=Rated primary current.

5.Iout=Rated secondary current.

6.Iprimax=Sensed max primary current.

7.Loutmax=Sensed max secondary current.

8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following

equation RL=Vout*Nsec/Ipri



ABSOLUTE MAXIMUM RATINGS

Operating free air temperature range

-40℃ to 60℃

Storage temperature range

-40℃ to 80℃

SOLDERING INFORMATION

Peak wave solder temperature

300℃ for 10Seconds

Pin finish

Tin


78

Mechanical Specifications


789

Through rapid response to market changes, we better serve the market and solve the problem of increasing people's actual demand for Portable Electrical Current Transformer CT PT Vt Test Instrument Voltage Testing with High Accuracy 0.1%. Although our business continues to grow and develop, we always focus on helping customers solve problems. Based on this, we have also achieved our best business results. We wish to work along with you and request common enhancement.

Hot Tags: 1: 1000 high accuracy current transformer, China, manufacturers, customized, quotation, low price, made in China, Three Phase Current Transformer 1 3000, Digital Meter Current Transformers, Open Residual Current Transformer, 200A 5A Center Through Current Transformer, Class 0 1 High Accuracy Transformer, DC Residual Current Sensor

[[ProKeywords]]
Send Inquiry