Power Supply Current Electronic Low Frequency Toroidal Transformer

Power Supply Current Electronic Low Frequency Toroidal Transformer

This current transformer is suitable for installation on the three-phase bushing of the ring switchgear and the switch on the main cabinet for the measurement and protection of three-phase current and zero-sequence current.

  • Product Introduction
Our highly skilled craftsmen have devoted all their efforts to the creation of each of our High Frequency Current Transforemr 1: 1000, Split-core Residual Current Transformer, Center Throughcurrent Transformer at every step. Innovation, enterprising, honesty and pragmatism are our entrepreneurial spirit. Presently, we are looking forward to even greater cooperation with overseas customers based on mutual benefits. We strive to improve the core competitiveness of the enterprise. We follow strict standards and quality inspection methods to ensure product quality and provide good sales service.

89

Three phase current transformer


Description

¨   50/60 Hz,Three- Phase,AC Current Sensor

¨   Dynamic Range from 10A to 100Amps

¨   Meets IEC62053-21 class 1

¨   Meets IEC 60044-1 class 0.1 Phase error < 5'

¨   Very low temperature coefficient

¨   Meets UL class B (130℃) thermal insulation system

¨   Meets UL 94V-0

¨   AC isolation resistance: 4KV for 60s

¨   Max. operation voltage:  AC660V



Application

•   Electricity meter

•   Recording

•   Power monitoring

•   Energy management

•   Alternative energy monitoring


ELECTRIC SPECIFICAITON AT 25

Model number

Turns Ration

Ipri4

Iout5

Iprimax6

Ioutmax7

Accuracy Class3

RL8

Weight

Frequency

range

Amps

mA

Amps

mA


Ohms

(g)

(Hz)

LO-TP0002

1:2000

10

5

160

80

0.1

20


50-60

Note:

1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.

2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.

3.Accuracy class per IEC60044-1Table 11.

4.Ipri=Rated primary current.

5.Iout=Rated secondary current.

6.Iprimax=Sensed max primary current.

7.Loutmax=Sensed max secondary current.

8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following

equation RL=Vout*Nsec/Ipri



ABSOLUTE MAXIMUM RATINGS

Operating free air   temperature range

-40 to 125

Storage temperature range

-40 to 65

LEADS  INFORMATION

UL2649 22AWG BLACK

150CM±10MM


Mechanical Specifications

LO-TP0002 DIMENSION

Through independent research and development, we innovated a series of Power Supply Current Electronic Low Frequency Toroidal Transformer with independent intellectual property rights. We actively carry out the transformation of the internal management of the company, as well as staff training. Make sure you note that samples are available before we start our business.

Hot Tags: three phase current transformer 1: 2000, China, manufacturers, customized, quotation, low price, made in China, Ground Fault Zero Sequence Current Sensor, Low Impedance Restricted Earth Fault, General Electric Current Transformer, Single Phase Current Transformer, Electrical Current Transformer High Accuracy CT, Residual Current Transformer High Current factory

[[ProKeywords]]
Send Inquiry