DC Immune Current Transducer 1: 2000
- Product Introduction
Wuxi Liou Electronics Co.,Ltd is one of the leading manufacturers and suppliers of dc immune current transducer 1: 2000 in China. Our factory offer high quality customized products made in China with low price. Welcome to contact us for quotation.

Introduction
A DC Immune Current Transformer (DCICT) is a specialized electrical device designed to accurately measure alternating current (AC) in the presence of direct current (DC). Unlike conventional current transformers, which can be significantly affected by DC components, DCICTs are specifically engineered to minimize or eliminate the influence of DC on their measurement.
Features
- 50/60 Hz,Single Phase,AC Current Sensor
- Dynamic Range from 5 to 80Amps
- Meets IEC 60044-1/IEC61869-2 Class 0.1/0.2
- Immune to external AC magnetic field. Immune to DC current & DC magnetic field
- Very low temperature coefficient
- Meets UL class B (130ºC) thermal insulation system
- Meets UL 94V-0
- AC isolation resistance: 4KV for 60s
- Resistant to DC component :≤±3%
Applicaiton
- Power Electronics: Measuring currents in power electronic circuits, such as inverters, rectifiers, and motor drives.
- Renewable Energy Systems: Monitoring currents in solar panels, wind turbines, and other renewable energy sources.
- Industrial Control Systems: Measuring currents in various industrial processes and equipment.
- Electrical Grids: Monitoring currents in transmission and distribution lines.
|
ELECTRIC SPECIFICAITON AT 25℃ |
||||||||||
|
Model number |
Turns Ration |
Ipri4 |
Iout5 |
Iprimax6 |
Ioutmax7 |
Resistant to DC component |
Accuracy Class3 |
RL8 |
Magnetic shield |
Frequency range |
|
Amps |
mA |
Amps |
mA |
% |
|
Ohms |
Tesla |
(Hz) |
||
|
LO-ADC720DT |
1:2500 |
5 |
2 |
60 |
24 |
≤±3% |
0.1/0.2 |
5-20 |
300mT |
50-60 |
|
1:2000 |
5 |
2.5 |
60 |
30 |
||||||
|
1:2500 |
10 |
4 |
60 |
24 |
≤±3% |
|||||
|
1:2000 |
10 |
5 |
60 |
30 |
||||||
|
1:1000 |
10 |
10 |
60 |
60 |
||||||
|
1:2500 |
5 |
2 |
80 |
32 |
≤±3% |
|||||
Note
1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.
2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.
3.Accuracy class per IEC60044-1Table 11.
4.Ipri=Rated primary current.
5.Iout=Rated secondary current.
6.Iprimax=Sensed max primary current.
7.Loutmax=Sensed max secondary current.
8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following
equation RL=Vout*Nsec/Ipri
|
ABSOLUTE MAXIMUM RATINGS |
|
|
Operating free air temperature range |
-40ºC to 85ºC |
|
Storage temperature range |
-40ºC to 100ºC |
|
LEADS INFORMATION |
|
|
24AWG UL1569 Lead wires |
Leads length:L±5mm |
|
Stripped and tinned |
L2+1/-0mm |
| Tube Length | L1±5mm |
Dimensions

Wuxi Liou Electronics Co Ltd
Hot Tags: dc immune current transducer 1: 2000, China, manufacturers, customized, quotation, low price, made in China, DC Immune Current Transducer 1 2000, DC Immune Current Transformers, High Precision DC Immune Current Transformer, DC Immune Current Transducer 1: 2000, DC Immune Current Sensor, 1 2500 DC Immune Current Transducer