Six Causes of Failure of Micro Electrical Current Transformers
Jan 06, 2022| 1. When it is found that the Electrical Current Transformer has a secondary disconnection, it is necessary to distinguish the fault occurrence point and the different phases of the switch, so as to judge whether the entire protection will be affected, report and schedule the situation, and directly eliminate the possible misoperation;
2. The primary load current can be reduced as much as possible. If the ct is seriously damaged, the load should be transferred, and the power should be cut off for processing and inspection.
3. Short circuit twice at the nearest test terminal, check the open circuit point, and confirm that the short circuit is correct;
4. If a spark occurs during the short circuit, it means that the short circuit is effective, and it also means that the fault point is at the short circuit of the contact;
5. On the contrary, if there is no spark during the short circuit, it means that the short circuit has no effect, and the fault point should not be in the circuit;
6. Change the CT's secondary short-circuit operation to power-off check. When turning on or off the CT again, use insulating tools and wear gloves with good insulating effect.
Many friends don't know what is the difference between measuring Electrical Current Transformer and Electrical Current Transformer's protection, but in fact they are the same, measuring the working principle of Electrical Current Transformer's electromagnetic induction will display the current meter, and Protecting Electrical Current Transformer is different Yes, when the current is too large, the current will be passed between the relay control circuit breaker and the contactor, and the power will be cut off directly, which can effectively protect the lines and equipment.
Winding protection Electrical Current Transformer function is mainly reflected in the system short-circuit fault. As the short-circuit fault current increases, it is dozens of times higher than the rated current under normal conditions, which is a large line current. The Electrical Current Transformer of the protection winding can be equipped with suitable measurement accuracy to make the protection work properly.
The basic Electrical Current Transformer for measuring and measuring is the secondary winding. The key is to ensure that the load current can complete the work within the normal rated current range to ensure the accuracy of the measurement. But when the system is short-circuited, the primary and secondary current value of the transformer may be much larger than the rated current, and even if the secondary winding of the measurement error is large, it will not have any practical effect, mainly because the short-circuit time is short, and the tripping protection Therefore, for the measurement and measurement of the secondary winding of the Electrical Current Transformer, the accurate liquid level can reflect the accuracy of the measurement time. Therefore, the accuracy of the secondary winding liquid level is different, so the entire measurement and measurement method will also be different.