Relay Protection 0.5va High Precision Current Transformer

Relay Protection 0.5va High Precision Current Transformer

The current transformer is divided into a current transformer for measurement and a current transformer for protection; the function of the current transformer for measurement is used to measure (charge) and measure the current of the operating device

  • Product Introduction
Our 50A Current Transformer, Zero Sequence Ground Fault Current Transformer, Ground Fault Zero Sequence Current Sensor has undergone rigorous performance testing and repeated field testing, which ensures its good quality and stable performance. We have perfect training mechanism, allowing every employee to progress and improve. We insist on technological innovation and quality first in order to provide customers with an efficient, high-quality and accurate solution with high-tech products and a complete service system.

Introduction

The current transformer is divided into a current transformer for measurement and a current transformer for protection; the function of the current transformer for measurement is used to measure (charge) and measure the current of the operating device; the current transformer for protection mainly and the relay device Cooperate, when the line is short-circuit overload and other faults, provide a signal to the relay device to cut off the fault circuit to protect the safety of the power supply system.


Precision Current Transformer(001)


Absolute Maximum Ratings


Operating free air temperature range

-40ºC to 85ºC

Storage temperature range

-40ºC to 100ºC

Leads Information

24AWG UL1007 Lead wires

Leads length:105±5mm

Stripped and tinned

4±2mm

Advantages

1. High and low voltage completely isolated, high safety, excellent insulation performance, no iron core, eliminating magnetic saturation and ferromagnetic resonance.

2. Good anti-electromagnetic interference performance, no open circuit high voltage danger on the low voltage side.

3. Large dynamic range, high measurement accuracy and wide frequency response range.

4. Data transmission anti-interference ability.

5. Small size and light weight.

Precautions

1. When the current transformer is verified, the current ratio of the standard current transformer to the current transformer to be tested must be the same.

2. Strictly follow the wiring shown in the figure.

3. Before testing the transformer, you must first test whether the load box is accurate.

4. During the verification process, it is forbidden to open the secondary winding.

5. Demagnetize before the transformer is verified. The demagnetization line is shown in Figure 4.

6. Open the circuit twice, adjust the regulator evenly and slowly, so that the indication of the dial indicator increases from 0 to 100%, and then evenly and slowly drops to zero. Repeat this process 2 to 3 times. The secondary winding should be shorted before the power is turned off after the demagnetization is completed.

7. The wiring schematic diagram of the current transformer with current riser is basically the same as the above wiring diagram, except that the output winding of the current riser and the primary winding of the transformer are the same winding, and the rest are the same.

QQ图片20200716135417_meitu_1

We guarantee to give you a timely reply, and look forward to working with all merchants to grow together, through joint efforts, to provide the best quality Relay Protection 0.5va High Precision Current Transformer for you. You should really feel totally free to make contact with us for more aspects. Along with market trends, we use professional and scientific management to improve the quality of our operations.

Hot Tags: precision current transformer, China, manufacturers, customized, quotation, low price, made in China, Current Sensor Transformerhigh Precision CT, Split current transformer core, Split core Residual Current Transformer, Mini Split core AC Current Transformer, Current Transformer For Energy Meter, Switching Power Supply Current Transformer