Stable Output Low Voltage Transformer 12-15VAC 120VAC Transformation

Stable Output Low Voltage Transformer 12-15VAC 120VAC Transformation

Our products are low cost, high precision, wide linear range, low phase shift error, and resistant to combustion casings and fillers.This sensor has a wide range of applications and is well received by customers.

  • Product Introduction
Our company relies on the brand as the goal, the quality assurance for the life and continuously improves Residual Current Transformer Current factory, 100mA AC Current Transformer, Protection Electrical Current Transformer Center and the service quality. We can guarantee the supply of our company. At the same time, we uphold the 'customer first' principle to provide you with intimate service. It's our responsibility to guarantee the quality of products. Since our establishment, we have been aggressive and innovating constantly. With our good corporate reputation, unique business style, and strong market development capabilities, we have achieved outstanding results one after another.

56


Description:


  • 50/60 Hz,Single Phase,AC Current Sensor

  • Dynamic Range from 0.1 to 9Amps

  • Meets IEC62053-21 class 1

  • Meets IEC 60044-1 class 0.1 Phase error < 5'

  • Immune to external AC magnetic field. Immune to DC current & DC magnetic field

  • Very low temperature coefficient

  • Meets UL class B (130℃) thermal insulation system

  •  Meets UL 94V-0

  • AC isolation resistance: 4KV for 60s


Application:

  • Electricity meter

  • Recording

  • Power monitoring

  • Energy management

  • Alternative energy monitoring


 

ELECTRIC SPECIFICAITON AT 25

Model number

Turns Ration

Ipri4

Iout5

Iprimax6

Ioutmax7

RS

Accuracy

Class3

RL8

Weight

Frequency range

Amps

mA

Amps

mA

Ohms


Ohms

(g)

(Hz)

LO-EM0001

1:300

1.5

5

9

30


0.1

40

40

50-60

Note:

1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.

2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.

3.Accuracy class per IEC60044-1Table 11.

4.Ipri=Rated primary current.

5.Iout=Rated secondary current.

6.Iprimax=Sensed max primary current.


Schematic diagram:

4

Dimensions:

lo-em0001 dimensions




If you have any questions about our Stable Output Low Voltage Transformer 12-15VAC 120VAC Transformation, please let me know, and we will reply to you in a satisfactory manner. The joint efforts of all staff of our company provide high-quality service for customers, and constantly improve the efficiency and comprehensive strength, so that the enterprise has achieved considerable development. Our company has always been a reasonable price, thoughtful service to provide customers with high-quality products to meet the needs of customers in many aspects and at the same time to provide users with perfect after-sales service.

Hot Tags: low voltage transformer, China, manufacturers, customized, quotation, low price, made in China, High current Zero Sequence Current Transformer, Toroidal Current Transformer, Split core DC current sensors, Residual Current Transformer High Current factory, Zero Phase Sequence Current Transformer, Clamp On Current Transformer