video

High Precision Current Transformer 1:2500 With Bus Bar 0.1 Class

A CT meter is simply a meter that is used in conjunction with instrument transformers known as current transformers. These are also known as CTs. In electrical metering, meters are divided into two types. There are self-contained meters. In addition there are transformer-rated meters. Transformer-rated meters are also known as CT meters.

  • Product Introduction

Wuxi Liou Electronics Co.,Ltd is one of the leading manufacturers and suppliers of high precision current transformer 1:2500 with bus bar 0.1 class in China. Our factory offer high quality customized products made in China with low price. Welcome to contact us for quotation.

 

67

 

                                                                       

 

Description

 

50/60 Hz,Single Phase,AC Current Sensor

Dynamic Range from 0.25 to 80Amps

Meets IEC62053-21 class 1

Meets IEC 60044-1 class 0.1 Phase error < 5'

Immune to external AC magnetic field. Immune to DC current & DC magnetic field

Very low temperature coefficient

Meets UL class B (130℃) thermal insulation system

Meets UL 94V-0

AC isolation resistance: 4KV for 60s

 

    

Application

• Electricity meter

• Recording

• Power monitoring

• Energy management

• Alternative energy monitoring

 

ELECTRIC SPECIFICAITON AT 25℃

Model number

Turns Ration

Ipri4

Iout5

Iprimax6

Ioutmax7

RS

Accuracy

Class3

RL8

Weight

Frequency

range

Amps

mA

Amps

mA

Ohms

 

Ohms

(g)

  (Hz)

LO-EM0005

1:2500

  5

2

80

    32

 

0.1

20

 

  50-60

 

 

 

 

 

 

 

 

Note:

1.Output voltage is proportional to the derivative(di/dt)of the input current based on the Rogowski Coil principle.

2.All current and voltages assumed to be sinusoidal waveforms at Fr, the constant rated frequency in Hz, measured as RMS value.

3.Accuracy class per IEC60044-1Table 11.

4.Ipri=Rated primary current.

5.Iout=Rated secondary current.

6.Iprimax=Sensed max primary current.

7.Loutmax=Sensed max secondary current.

8.RL=Terminating resistance. Varying terminating resistance increases or decreases output Voltage /Ampers according to following

equation RL=Vout*Nsec/Ipri

 

ABSOLUTE MAXIMUM RATINGS

Operating free air temperature range

-40℃ to 85℃

Storage temperature range

-40℃ to 100℃

LEADS INFORMATION

24AWG UL1569 Lead wires

Leads length:105±5mm

Stripped and tinned

                                       4±2mm

 

78

 

 

 

 

Mechanical Specifications

 

LO-EM0005DIMENISONS

 

 

Hot Tags: high precision current transformer 1:2500 with bus bar 0.1 class, China, manufacturers, customized, quotation, low price, made in China, Low Voltage Transformer, High Voltage Current Transformer, Class 0.1 High Accuracy Transformer, Sensor Current Sensor Transformer, Current Transformer For Energy Meter, Electricity Meter Current Transformer