The scope of application of zero sequence current transformer

Jun 16, 2023|

CXRD-LJ series zero-sequence current transformer is cable type, adopts ABS engineering plastic shell, resin cast into a fully sealed, good insulation performance, beautiful appearance, high sensitivity, good linearity, reliable operation, convenient installation, etc., its performance is excellent In the general zero-sequence current transformer. Wide range of applications, not only suitable for electromagnetic relay protection, but also suitable for electronic and microcomputer protection devices. coil grounding) select the appropriate zero-sequence current transformer.

Zero-sequence current transformers are used in a wider range, not only suitable for electromagnetic relay protection, but also for electronic and microcomputer protection devices. Users can use neutral point effective grounding or neutral point non-effective grounding according to the operation mode of the system. Select the corresponding zero-sequence current transformer.

The zero-sequence current transformer is used in conjunction with the relay protection device and the signal when the power system generates zero-sequence grounding current, so that the device components operate to realize protection or monitoring. DH—LJ series zero-sequence current transformers are cable-type, with ABS engineering plastic casing, resin cast into a fully sealed, good insulation performance, and beautiful appearance. It has the characteristics of high sensitivity, good linearity, reliable operation and convenient installation. The performance of the transformer is better than that of the general zero-sequence current transformer, and it can be used in a wider range. It is not only suitable for electromagnetic relay protection, but also for electronic and microcomputer protection devices. Users can effectively ground the neutral point or neutral point according to the operation mode of the system. If the point is not effectively grounded, select the corresponding zero-sequence current transformer. Principle: The basic principle of zero-sequence current protection is based on Kirchhoff's current law: the algebraic sum of the complex current flowing into any node in the circuit is equal to zero. When the line and electrical equipment are normal, the vector sum of the currents of each phase is equal to zero. Therefore, the secondary side winding of the zero-sequence current transformer has no signal output, and the actuator does not operate. When a ground fault occurs, the vector sum of the currents of each phase is not zero, the fault current causes magnetic flux to be generated in the ring iron core of the zero-sequence current transformer, and the induced voltage on the secondary side of the zero-sequence current transformer makes the actuator act and drive The tripping device switches the power supply network to achieve the purpose of ground fault protection.

Send Inquiry