2019-5-01Smart metering device and current signal for waterproof split core current tr...
The waterproof split core current transformers has a core when it is used. Generally, the large current of the primary side is converted into a small current of the secondary side, and then effectivel -

2019-4-30Circuit monitoring and working principle of power current transformer
When the power current transformer is used, its main function is to convert the large current in the AC circuit into a certain proportion of small current, so that it can be used for measurement and r -

2019-4-29Wiring principle and safety requirements for power current transformer
When the power current transformer is used, it will be high voltage due to the primary side of the high-voltage power current transformer. When the primary and secondary coils are damaged by the insul -

2019-4-23Split core current transformers usage precautions
1. It is necessary to check whether the appearance is deformed before use, otherwise it will affect the test accuracy; 2. Before use, check that the end face of the iron core is clean. Wipe it with -

2019-4-22Zero phase current transformers have high reliability and wide application
The zero phase current transformer can be set as appropriate during operation, so that the zero-sequence current when the ground fault occurs can be detected, so that the faulty circuit can be cut off -

2019-4-21Ground fault residual current prevents ground fault from causing electrical fire
The ground fault residual current will effectively install its protection device at the end of the line during the operation. Under normal circumstances, the short circuit setting current of the circu -

2019-4-20The use method and operation process of zero phase sequence current transformer
The zero phase current transformer is in the process of use, whether it is a longitudinal fault, a lateral fault, or a normal or abnormal asymmetry. In the operation, as long as the zero-sequence volt -

2019-4-19Wide application and operation mode of ground fault zero sequence current sensor
The fundamental principle of the ground fault zero sequence current sensor is the Kirchhoff current law. The algebraic sum of the complex current flowing into any node in the circuit during operation -

2019-4-17Installation requirements for high current split core current transformers ar...
The high current split core current transformer is very suitable for current measurement, signal sampling and microcomputer protection of 10KV AC power system electrical equipment during use. The high -

2019-4-15Threading method and installation position of residual current sensor
Before the threading of the residual current sensor, the phase line, N line and PE line in the power grid should be separated. The phase line and the N line must pass through the residual current sens -

2019-4-12Precautions for residual current sensor wiring
In order to avoid false alarms, the residual current sensor must distinguish the phase line, N line and PE line in the power grid before wiring. -

2019-4-10The role and principle of zero sequence current transformer
Zero sequence current transformer are typically used in conjunction with relay protection devices or signals when the power system produces zero-sequence ground currents to cause device components to