2022-4-04Main Factors Affecting Current Transformer Error
(1) The influence of primary current. When the primary current of the current transformer is very small, the error caused by it will increase; when the primary current is larger than the rated current -

2022-4-01Operating requirements for miniature current transformers
In order to ensure the long-term normal use of the miniature current transformer, certain requirements should be met during its operation. First of all, the miniature current transformer must not run -

2022-3-19Zero Sequence Current Transformer must not open the secondary side during ope...
Drying treatment is necessary, when the insulation resistance of the secondary coil of the Zero Sequence Current Transformer is lower than 10~20 megohms. After the insulation is restored, it can be us -

2022-3-18Precautions for using Zero Sequence Current Transformer
The polarity connection of Zero Sequence Current Transformer should be correct. Zero Sequence Current Transformer is generally marked with decreasing polarity. If the polarity connection is incorrect, -

2022-3-17Zero Sequence Current Transformer protects against failure
Zero Sequence Current Transformer is a current transformer specially used to transform zero sequence current. When the zero-sequence grounding current is generated in the power system, it is used in c -

2022-3-16How the Zero Sequence Current Transformer device works better
The secondary side of Zero Sequence Current Transformer must not be opened during operation. Once the secondary side is opened, it will burn out due to excessive iron loss and high temperature, or the -

2022-3-14Definition of Zero Sequence Current Transformer
Zero Sequence Current Transformer is also called residual current transformer, grounding current transformer or leakage current transformer. It is used to detect neutral unbalanced current and is gene -

2022-3-11How Zero Sequence Current Transformer Neutralizes
The zero-sequence current is caused by the unbalance of three phases A, B, and C on the power grid. There will be zero-sequence current on the N line. A Zero Sequence Current Transformer is installed -

2022-3-09How Zero Sequence Current Transformer Does Equipment Maintenance
Zero Sequence Current Transformer has the characteristics of high flexibility, good linearity, reliable operation and convenient equipment. The function of the Zero Sequence Current Transformer is bet -

2022-3-07How the Zero Sequence Current Transformer is used in combination
The Zero Sequence Current Transformer looks like two circular iron boxes in appearance, but it is also a component of the diesel generator. Its structure is similar to that of an ordinary through-core -

2022-3-05What are the characteristics of Zero Sequence Current Transformer in use?
The Zero Sequence Current Transformer cannot operate under the condition of exceeding the rated capacity. The overload will cause the passing current to exceed the rated current of the product, result -

2022-3-03The significance of using the protection device Zero Sequence Current Transfo...
The Zero Sequence Current Transformer is generally used to detect "unbalanced" currents (leakage currents) on the main circuit loop through the transformer, because on the main loop through