2022-2-13Equipment needed to verify the Electrical Current Transformer
1. Transformer calibrator: measure the error between the standard transformer and the tested transformer, and display the working current. 2. Standard Electrical Current Transformer: It is used as a s -

2022-2-12How to choose Electrical Current Transformer
(1) The rated primary current should be within the range of 20% to 120% of the running current. (2) The rated primary voltage of the Electrical Current Transformer is the same as the operating voltage -

2022-2-11Problems that should be paid attention to in the operation of Electrical Curr...
1. The secondary side of the Electrical Current Transformer must not be opened during operation. Once the secondary side is opened, it will burn out due to excessive iron loss and high temperature, or -

2022-2-10Precautions for the use of current transformers
1. Select the rated current ratio of the current transformer according to the magnitude of the measured current, that is, to make the primary rated current of the current transformer greater than the -

2022-2-09Electrical Current Transformer wiring principles and precautions for use
The wiring principle of Electrical Current Transformer 1. Open circuit is not allowed. The secondary open circuit can easily lead to safety accidents, because the secondary open circuit will cause the -

2022-2-08Three roles of Electrical Current Transformer
1. Expand the range of AC instruments Because the Electrical Current Transformer is made based on the principle of a transformer, it has a certain current ratio. When using electricity, the amount of -

2022-2-07What should be paid attention to when the Electrical Current Transformer is c...
In actual operation, there is a basic principle when the current is connected in series: the primary winding should be connected in series with the circuit of the power supply under test, and the seco -

2022-2-06How to reduce the phase difference of Electrical Current Transformer
1. Installing circuit breakers on the secondary side can make the Electrical Current Transformer safer and more reliable during operation, so the choice of circuit breakers must be appropriate. 2. In -

2022-2-05Prevention of Open Circuit of Electrical Current Transformer Secondary Circuit
(1) Short-circuit protection equipment such as fuses cannot be installed in the secondary circuit; (2 The secondary circuit is not allowed to switch, if it is necessary to switch, it is necessary to t -

2022-2-04Electrical Current Transformer Wiring Inspection Method
1. In order to check whether there is disconnection and short circuit on the secondary side, disconnect the wires connected to the A-phase voltage terminal and the C-phase voltage terminal of the elec -

2022-2-03Operational Requirements for Electrical Current Transformer
First of all, the product cannot be operated under the condition of exceeding the rated capacity for a long time. The long-term overload will cause the passing current to exceed the rated current of t -

2022-2-02Analysis of Influencing Factors of Miniature Current Transformer Error
From a structural point of view, the so-called Miniature Current Transformer mainly includes three major components, namely the iron core, the primary coil and the secondary coil. Due to the existence