2022-5-04Operating rules for miniature current transformers
When it comes to our miniature current transformers, it does a good job of keeping us safe during construction. Also, as far as our miniature current transformer is concerned, it is actually an electr -

2022-5-03Influencing Factors of Miniature Current Transformer Error
1. The internal parameters of the current transformer; 2. The size of the core section; 3. The number of turns of the coil; 4. Reduce the core loss and improve the magnetic permeability. As for the mi -

2022-5-02The method of current transformer wiring
(1) Current sensor wiring. This wiring method is used to accurately measure single-phase load current or load balance in a three-phase power supply system. (2) Star connection consisting of three curr -

2022-5-01Method for abnormal inspection of miniature current transformer
1. When verifying the current transformer, the current ratio of the standard current transformer must be the same as the current ratio of the current transformer under test. 2. Exactly follow the line -

2022-4-30Reasons for six faults of miniature current transformers
1. When it is found that the current transformer has a secondary disconnection, it is necessary to distinguish the fault occurrence point and the different phases of the switch, so as to judge whether -

2022-4-29The following four points need to be paid attention to when using Miniature C...
1. The polarity of the current transformer must be connected correctly. Usually current transformers use subtractive polarity labels, so if the polarity connection is wrong, it will directly affect th -

2022-4-28Reasons for Demagnetization of Electrical Current Transformer
When the current suddenly decreases, the transformer core is likely to cause magnetic losses. For example, under high current conditions, the Electrical Current Transformer suddenly cuts off the power -

2022-4-27Principles of use of current transformers
1) The wiring of the current transformer should follow the series connection principle: that is, the primary winding should be connected in series with the circuit under test, and the secondary windin -

2022-4-26What equipment is required to verify the current transformer
1. Transformer calibrator: measure the error between the standard transformer and the tested transformer, and display the working current. 2. Standard current transformer: It is used as a standard in -

2022-4-25Problems that should be paid attention to in the operation of current transfo...
1. The secondary side of the current transformer should not be opened during operation. Once the secondary side is open, it will burn out due to excessive iron loss and high temperature, or the second -

2022-4-23How to use the current transformer
1. The wiring of the current transformer should follow the series principle: that is, the primary winding should be connected in series with the circuit under test, and the secondary winding should be -

2022-4-22Precautions for low-voltage current transformers:
1. Select the corresponding specification products according to the parameters such as primary current and busbar cross-section. The primary wire passes through the transformer window. Open the flip c