2022-1-11How to handle secondary open circuit faults in Miniature Current Transformer
1. When we see the secondary open circuit of the current transformer, first distinguish which current loop is, and then judge the phase of the open circuit to see if it affects the protection, and the -

2022-1-10Operation rules of Miniature Current Transformer
When it comes to our Miniature Current Transformer, it does a great job of keeping us physically present during construction. Also, in the case of our Miniature Current Transformer, it's actually -

2022-1-09Miniature Current Transformer Error Influencing Factors
1. The internal parameters of the current transformer; 2. The size of the core section; 3. The number of turns of the coil; 4. Reduce the core loss and improve the magnetic permeability. As for the Mi -

2022-1-08What should I pay attention to when using the tiny Electrical Current Transfo...
As for the voltage micro-transformer, it is used in the power supply line. Regarding the difference in current size, we need to convert it into a relatively consistent current in order to facilitate o -

2022-1-07Tiny Electrical Current Transformer Check Exception Method
We can use the principle of volt-ampere characteristics, because the core Electrical Current Transformer is gradually saturated, if the power flow is short-circuited, the Electrical Current Transforme -

2022-1-06Six Causes of Failure of Micro Electrical Current Transformers
1. When it is found that the Electrical Current Transformer has a secondary disconnection, it is necessary to distinguish the fault occurrence point and the different phases of the switch, so as to ju -

2022-1-05The following four points need to be paid attention to when using the Micro E...
1. The polarity connection of the Electrical Current Transformer must be correct. Usually Electrical Current Transformers use subtractive polarity labels, so if the polarity connection is wrong, it wi -

2022-1-04Power Current Transformer explosion prevention measures
(1) Check whether the lead connector in the primary terminal of the transformer is in good contact The lead joints of the primary terminals of the Power Current Transformer must be in good contact, an -

2022-1-03The correct use of Power Current Transformer
1. The wiring of the Power Current Transformer should follow the series principle: the primary winding should be connected in series with the circuit under test, and the secondary winding should be co -

2022-1-02Zero Sequence Current Transformer application and requirements
Zero Sequence Current Transformer is also called protection current transformer. The requirement for this type of transformer is that the error does not exceed the specified range under specified cond -

2022-1-01What are the equipment required to verify the Power Current Transformer
1. Transformer calibrator: Measure the error between the standard transformer and the tested transformer, and show the working current. 2. Standardizing Power Current Transformer: It is used as a stan -

2021-12-31Precautions for Residual Current Transformer wiring
1. Be sure to distinguish the phase wires, N wires and PE wires in the power grid before wiring, otherwise problems will occur, resulting in inaccurate measurement data and false alarms. 2. The phase