2021-9-21Problems in the installation of zero-sequence current transformers and their ...
1) The installation position of the zero-sequence current transformer and the grounding wire of the cable terminal is wrong, mainly due to the problem of whether the 10 kV cable steel shield grounding -

2021-9-20How to choose the right Power Current Transformer
1. Accuracy In most applications, measurement accuracy has a direct impact on the efficiency of the entire system. The accuracy of the power calculation obviously depends on the accuracy of the Power -

2021-9-19How to install and use Power Current Transformer
1. The installation of Power Current Transformer, depending on the equipment configuration, has the following situations: ①Install the Power Current Transformer on the metal frame. ②In the place where -

2021-9-18Why can't Power Current Transformer run open circuit
The structure of the electromagnetic Power Current Transformer is similar to the general power transformer. It is also composed of iron core and coil. The difference between them is that the primary c -

2021-9-17Causes of Burning of Power Current Transformer
1. Install circuit breakers to prevent branch faults from power outages of the entire line, especially to ensure that the branch circuit breakers can reliably trip. 2. Connect the Power Current Transf -

2021-9-16Power Current Transformer wiring inspection
(1) In order to find out whether there are common faults such as disconnection and short-circuit faults on the secondary side of the Power Current Transformer, the wires connected to the phase A volta -

2021-9-15Preventive Measures for Burning Power Current Transformer
1. Reasons for the destruction of Power Current Transformer (1) The Power Current Transformer is opened for the second time, which generates high voltage and burns out the Power Current Transformer. ( -

2021-9-14What are the reasons for the burning of the Power Current Transformer
1. Install circuit breakers to prevent branch faults from power outages of the entire line, especially to ensure that the branch circuit breakers can reliably trip. 2. Connect the Power Current Transf -

2021-9-13Wiring principle of Power Current Transformer
(1) No open circuit is allowed on the secondary side of the Power Current Transformer. The secondary open circuit may produce serious results, one is that the iron core is overheated, and even the tra -

2021-9-12Measures to Determine the Saturation Point of Zero Sequence Current Transformer
The direct experimental method is to bring a practical load on the secondary side, pass current from the primary side, and observe the secondary current to find the saturation point of the zero-sequen -

2021-9-11What are the precautions during the operation of the Residual Current Transfo...
The secondary side of the residual current transformer must not be open during operation. Once the secondary side is open, it will burn out due to excessive iron loss and high temperature, or the volt -

2021-9-10What are the precautions during the operation of Power Current Transformer
The secondary side of the Power Current Transformer must not be open during operation. Once the secondary side is open, it will burn out due to excessive iron loss and high temperature, or the voltage