2022-7-29Six important factors in selecting AC current transformer
1. Determine the type according to the measurement object and environment First of all, carefully analyze the measurement work. The current transformer considers the measurement principle of the senso -

2022-7-27What is the accuracy level of current transformer
Because there is a certain error in the transformation current of the current transformer, the accurate grade is determined according to the transformation ratio error of the current transformer under -

2022-7-25Fault handling procedure of current transformer
(1) When the current transformer is found to have secondary open circuit, internal abnormal sound, serious oil leakage, temperature rise or smoke and other fault phenomena, it shall be powered off for -

2022-7-22Function and structure characteristics of miniature current transformer
Based on the analysis of the function and structure of micro current transformer, the primary winding and the circuit are connected in series with less turns (one or more turns). Therefore, the curren -

2022-7-20Wiring principle of current transformer
1. Open circuit is not allowed. The secondary open circuit is easy to cause accidents, because the secondary open circuit will cause the iron core to overheat and induce high voltage. Current transfor -

2022-7-18Precautions for use of current transformer
1. Generally speaking, the connection of current transformer is based on subtraction, so the sexual connection should be correct. Once the connection is wrong, the measurement will be inaccurate, or e -

2022-7-15Current transformer wiring inspection method
1. In order to check whether there is disconnection and short circuit on the secondary side, disconnect the wires connected to the A-phase voltage terminal and c-phase voltage terminal of the electric -

2022-7-13What problems should be paid attention to in the operation of open close curr...
1) The current transformer manufacturer shall not open the secondary side during operation. Once the secondary side is opened, it will lead to insulation breakdown due to excessive iron loss and high -

2022-7-11How to check the secondary open circuit fault of current transformer?
1) The indication of loop instrument decreases abnormally or is zero. For example, the current circuit used to measure the meter is open; The indication of three-phase ammeter will be inconsistent and -

2022-7-08Precautions for use of current transformer
(1) The polarity connection should be correct. Current transformers are generally marked according to the minus polarity. If the polarity connection is incorrect, it will affect the measurement, and e -

2022-7-06Wiring principle of current transformer
1) Open circuit is not allowed at the secondary side of current transformer. The secondary open circuit may have serious consequences. First, the iron core is overheated, and even the transformer is b -

2022-7-04Inspection and treatment method of open circuit and short circuit fault on se...
Since only a small impedance is allowed in the secondary circuit of the current transformer, it is close to the short-circuit state under normal working conditions, with very little sound, which is ge