2022-6-13Miniature Current Transformer Six Causes of Failure
1. When it is found that the current transformer has a secondary disconnection, it is necessary to distinguish the fault occurrence point and the different phases of the switch, so as to judge whether -

2022-6-11The following four points should be paid attention to when using Miniature Cu...
1. The polarity connection of the Power Current Transformer must be correct. Usually Power Current Transformers use subtractive polarity labels, so if the polarity connection is wrong, it will directl -

2022-6-10Correct construction method when installing Zero Sequence Current Transformer
1. Ensure that the inner diameter of the Zero Sequence Current Transformer is larger than the outer diameter of the cable terminal; 2. Try not to dismantle the Zero Sequence Current Transformer during -

2022-6-06Reasons for Grounding the Power Current Transformer
Power Current Transformer grounding is to ensure safety, one is equipment safety, and the other is personal safety. Because there is distributed capacitance between the primary winding and the seconda -

2022-6-01What are the precautions for using Power Current Transformer
(1) First of all, the Power Current Transformer is marked by the minus polarity. If the polarity is wrongly connected, it will not only affect the current measurement value, but also cause a short cir -

2022-5-20Operation and maintenance management of Residual Current Transformer
(1) After the Residual Current Transformer is put into operation, the user shall establish operation records and corresponding management systems (2) Electricity management personnel should at least c -

2022-5-19What equipment is required to verify the Electrical Current Transformer
1. Transformer calibrator: measure the error between the standard transformer and the tested transformer, and show the working current. 2. Standard Electrical Current Transformer: It is used as a stan -

2022-5-18Difference between Power Current Transformer and Zero Sequence Current Transf...
1. The methods used are different. The Zero Sequence Current Transformer is used to detect the zero-sequence current. Generally, all three live wires are passed through the inner hole of the transform -

2022-5-17How to measure the polarity of Power Current Transformer
1 DC method Use a 1.5~3V dry battery to connect its positive pole to the primary coil L1 of the transformer, and L2 to the negative pole. The secondary side K1 of the transformer is connected to the p -

2022-5-16Operation and Maintenance of Power Current Transformer
During operation, the secondary circuit of the Power Current Transformer may be opened by the terminal screws due to vibration, etc., causing the secondary circuit to open. If the Power Current Transf -

2022-5-14Reasons for overheating of secondary terminals of Power Current Transformer
The reason for the overheating of the secondary terminals of the Power Current Transformer: When the shorting piece of the secondary side terminal of the Power Current Transformer that is not connecte -

2022-5-13Power Current Transformer Explosion Precautions
(1) Check whether the lead connector in the primary terminal of the transformer is in good contact The primary terminal lead joint of the Power Current Transformer should be in good contact and the co