2021-11-08Electrical Current Transformer configuration requirements
1) The configuration of Electrical Current Transformer should try to avoid the dead zone of the main protection. When the protection is connected to the secondary winding of the transformer, it should -

2021-11-07Precautions for the use of Electrical Current Transformer
(1) The secondary side of the Electrical Current Transformer cannot be opened during operation. Electrical Current Transformer Under normal operating conditions, the secondary magnetomotive force is s -

2021-11-06How to maintain Electrical Current Transformer
(1) Check whether the outer insulating parts such as the outer casing are clean, and whether there are damages, cracks, and discharge traces. If it is found that the surface is dirty, or even flashove -

2021-11-05Things to keep in mind when using Electrical Current Transformer
First of all, you must ensure that the polarity connection of the Electrical Current Transformer is correct, otherwise the measurement will be affected, especially when multiple Electrical Current Tra -

2021-11-04How to install and use Electrical Current Transformer
Improper installation and use of the Electrical Current Transformer will cause the Electrical Current Transformer to burn, inaccurate measurement, and endanger the safety of equipment and operators. F -

2021-11-03Correct use of Electrical Current Transformer
1. The wiring of the Electrical Current Transformer should follow the series principle: that is, the primary winding should be connected in series with the circuit under test, and the secondary windin -

2021-11-02Correct use of Electrical Current Transformer
1. The wiring of the Electrical Current Transformer should follow the series principle: that is, the primary winding should be connected in series with the circuit under test, and the secondary windin -

2021-11-01Electrical Current Transformer open circuit prevention measures
(1) The secondary circuit of Electrical Current Transformer is not allowed to install short-circuit protection devices such as fuses; (2) Generally, the secondary circuit of the Electrical Current Tra -

2021-10-31Reasons that affect the error of the Electrical Current Transformer
1. The influence of the return conductor In an ideal situation: the electrical current transformer's secondary winding wires are evenly distributed on the toroidal iron core,-the secondary winding -

2021-10-30Attention to the daily use of Electrical Current Transformer
1. The electrical current transformer polarity connection must be correct Electrical Current Transformer generally reduces the polarity marking. If the polarity is not connected correctly, it will aff -

2021-10-29The difference between Electrical Current Transformer and Zero Sequence Curre...
1. The method used is different. The Zero Sequence Current Transformer is used to detect the zero sequence current. Generally, all three live wires are passed through the inner hole of the transformer -

2021-10-28Detection and treatment measures for common faults of Electrical Current Tran...
1. Deal with abnormal sound or iron core overheating. During the operation of the Electrical Current Electrical Current Transformer, if the secondary circuit is open or overloaded, it will produce abn