2023-3-03The difference between dry type and oil immersed current transformer
Dry current transformers use ordinary organic insulating materials as their insulating medium, which is different from oil-immersed current transformers and other types of current transformers. Dry cu -

2023-3-01Common Abnormalities of Current Transformers
When we use current transformers, the three-phase voltage is only unbalanced. When one phase drops, the other two phases are very normal and the line voltage is very abnormal or accompanied by sound a -

2023-2-27Precautions for current transformers
First of all, before we put it into use, we need to carry out a very careful inspection according to the items stipulated in the regulations. There are many inspection methods here. Here we will teach -

2023-2-24What is a current transformer?
The principle of the current transformer is based on the principle of electromagnetic induction. It will replace the large current on this side with the small current on both sides to measure the inst -

2023-2-22The phenomenon and reason of secondary open circuit of current transformer
The main reason for the open circuit of the current transformer in the test terminal in the AC current circuit is that the test terminal itself has quality and structural problems. During operation, t -

2023-2-20Wiring guidelines for current transformers
a. The current transformer cannot allow secondary open circuit The current transformer manufacturer solemnly warns everyone not to open the circuit twice when installing the current transformer, other -

2023-2-17Preventive Measures for Current Transformer Burning
1 Causes of current transformer burnout (1) The secondary open circuit of the current transformer generates high voltage and burns out the current transformer. (2) The service life of the current tran -

2023-2-15What tests should Power Current Transformer do?
When implementing the open-circuit method for demagnetization, select a winding with a smaller number of turns in the primary (or secondary) winding to pass 10% to 15% of the rated primary (or seconda -

2023-2-13How to deal with Power Current Transformer error
(1) Increase the cross-sectional area of the secondary cable or reduce the length of the cable. Increasing the cross-sectional area of the secondary cable of the current loop or reducing the length of -

2023-2-10How to take precautions against open circuit of current transformer?
When using a current transformer, it is necessary to abide by the electrical safety work regulations, so we can know that the secondary side must be reliably grounded. The main purpose of this is to p -

2023-2-08Current transformer wiring inspection method
1. In order to check whether the secondary side of the current transformer is disconnected or short-circuited, the wires connected to the A-phase voltage terminal and the C-phase voltage terminal of t -

2023-2-06Measurement of Full Point of Current Transformer
In order to accurately check whether the excessive current of the current transformer will be full and affect the correctness of the maintenance action, the direct and effective way is to carry the ac